Sperm morphology: Assessing the agreement between the manual method (strict criteria) and the sperm morphology analyzer IVOS

Date
1995
Authors
Kruger T.F.
Du Toit T.C.
Franken D.R.
Menkveld R.
Lombard C.J.
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Objectives: To correlate the percentage normal morphology reported by different observers and a computerized method (IVOS; Hamilton-Thorne Research, Beverly, MA) on a slide-by-slide basis using strict criteria: [1] Experienced observer (T.F.K.) versus experienced observer (R.M.), [2] experienced observer (T.F.K.) versus sperm morphology analyzer (IVOS), and [3] repeatability of normal and abnormal cells (IVOS). Design, Setting, Patients: Slides from 30 different patients from the Tygerberg IVF program were selected randomly. Microscopic fields and sperm cells were chosen randomly and percent normal morphology was recorded (objectives 1 and 2). The same slides were used and a cell-by-cell repeatability was done as outlined (objective 3). Results: Experiment 1 (objective 1): there was no significant bias between T.F.K. and R.M. The limits of agreement were 8.6% and -7.3%. The SDs were not significantly different (P = 0.1283). The Spearman correlation coefficient between readers was 0.83. Experiment 2 (objective 2): the same findings were reported but the limits of agreement were 12.1% and -15.5%. The Spearman correlation coefficient was 0.85. The limits of agreement was tighter below 20% normal forms (+8.4 and -6.6). Experiment 3 (objective 3) (repeatability): 255 cells were analyzed three times in succession. Estimating pairwise agreement, the κ statistic for the pairs are 0.85, 0.80, and 0.85, respectively, which compares favorably with the second canonical moment of 0.8329 (κ = 0.83). Discussion: The computer's ability to classify normal morphology per slide is promising. Below 20% normal forms, the limit of agreement is tight. Because of the 6% higher reading compared with the manual method, different thresholds possibly will be developed to identify subfertile from fertile patients. The computer gives excellent repeatability of normal and abnormal cells. Based on results obtained, this system can be of clinical value both in IVF units and andrology laboratories but more clinical data is required in this field.
Description
Keywords
accuracy, adult, article, automation, cell structure, clinical article, controlled study, human, human cell, male, observer variation, priority journal, spermatozoon, Automatic Data Processing, Cytological Techniques, Human, Male, Observer Variation, Reference Values, Reproducibility of Results, Software, Spermatozoa
Citation
Fertility and Sterility
63
1