Analysis of the calculation of the amplitude of accommodation

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/62198
Información del item - Informació de l'item - Item information
Título: Analysis of the calculation of the amplitude of accommodation
Autor/es: Coloma Torregrosa, Pilar | Fez Saiz, Dolores de | Pascual, Inmaculada | Camps, Vicente J.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV) | Holografía y Procesado Óptico
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Amplitude of accommodation | Spectacle accommodation | Ocular accommodation | Push-up method | Near point
Área/s de conocimiento: Óptica
Fecha de publicación: mar-2016
Editor: Elsevier
Cita bibliográfica: Optik. 2016, 127(6): 3474-3479. doi:10.1016/j.ijleo.2015.12.029
Resumen: The push-up method is routinely used to measure the amplitude of accommodation. In this method the diopter value corresponding to the nearest point that the eye can focus is determined, wearing his neutralizing lens, but not the value of the maximum diopter variation that makes the eye. The aim of this paper is to review the calculation described in the push-up method taking into account the real position of the near point of the eye. In the subjective push-up method, it is calculated the reciprocal of the distance from the lens until the test object at this position of first, slight, sustained blur. We calculated the differences between this value and the ocular amplitude of accommodation, taking into account that the eye is really looking at the image of first blur through the neutralizing lens. Experimental measurements were also taken to determine whether they were similar to theoretical values. The results obtained by the two calculation methods compared were in general significantly different and the difference was greater for young people with high ametropy. The theoretical results were in agreement with the experimental ones. According to the optometric information required must select the appropriate calculation method, since the values obtained in each of them are not comparable.
URI: http://hdl.handle.net/10045/62198
ISSN: 0030-4026 (Print) | 1618-1336 (Online)
DOI: 10.1016/j.ijleo.2015.12.029
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2015 Elsevier GmbH.
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1016/j.ijleo.2015.12.029
Aparece en las colecciones:INV - GOPV - Artículos de Revistas
INV - GHPO - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2016_Coloma_etal_Optik_final.pdfVersión final (acceso restringido)753,85 kBAdobe PDFAbrir    Solicitar una copia
Thumbnail2016_Coloma_etal_Optik_preprint.pdfPreprint (acceso abierto)1,26 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.