WEKO3
アイテム
{"_buckets": {"deposit": "d57c6051-c395-4468-8e40-0677c1ed054a"}, "_deposit": {"created_by": 1, "id": "25077", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "25077"}, "status": "published"}, "_oai": {"id": "oai:u-fukui.repo.nii.ac.jp:00025077", "sets": ["2285"]}, "author_link": ["72638", "72636", "72635", "72637"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1999-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "7", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "47", "bibliographic_titles": [{"bibliographic_title": "福井大学工学部研究報告"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This research aims at exploring possible application of the sonoluminescence phenomenon to water analysis. Experimental setups for measurement of sonoluminescence of water or sonic chemiluminescence of luminol aqueous solution have been prepared. Firstly an ultrasonic cleaner was used as a source of sonic wave. A glass tube used as a cell was directly immersed into water in the cleaner. Sonoluminescence of water from the cell was detected by a photomultiplier tube (PMT) . Although sonoluminescence of water was very weak, sonic chemiluminescence of luminol solution was strong enough in the ultrasonic cleaner. Secondly, an ultrasonic homogenizer was used as the sonic wave source. A micro tip of the ultrasonic homogenizer was directly immersed into a cell, which was a glass tube with internal diameter of I cm. Strong and stable sonoluminescence of water was observed. Experimental factors affecting the sonic chemiluminescence of luminol and sonoluminescence of water have been examined. The potential application of the sonoluminescence was also discussed.", "subitem_description_type": "Abstract"}]}, "item_10002_relation_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "TD00004606", "subitem_relation_type_select": "NCID"}}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "4298373", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "神埼, 幸輔"}], "nameIdentifiers": [{"nameIdentifier": "72635", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "呉, 行正"}], "nameIdentifiers": [{"nameIdentifier": "72636", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KANZAKI, Kousuke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "72637", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "WU, Xing-Zheng", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "72638", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-08-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AN00215401-047-01-001.pdf", "filesize": [{"value": "328.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 328300.0, "url": {"label": "AN00215401-047-01-001.pdf", "url": "https://u-fukui.repo.nii.ac.jp/record/25077/files/AN00215401-047-01-001.pdf"}, "version_id": "340212da-59af-497f-bf06-81636b3d12b9"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Sonoluminescence", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Luminol", "subitem_subject_scheme": "Other"}, {"subitem_subject": "UItrasonic Cleaner", "subitem_subject_scheme": "Other"}, {"subitem_subject": "UItrasonic Homogenizer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Water Analysis", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "超音波発光(ソノルミネッセンス)及びその水分析への応用に関する基礎研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "超音波発光(ソノルミネッセンス)及びその水分析への応用に関する基礎研究"}, {"subitem_title": "Basic Study on the Sonoluminescence Phenomenon and Its Potential Application to Water Analysis", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "1", "path": ["2285"], "permalink_uri": "http://hdl.handle.net/10098/3332", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-06-02"}, "publish_date": "2011-06-02", "publish_status": "0", "recid": "25077", "relation": {}, "relation_version_is_last": true, "title": ["超音波発光(ソノルミネッセンス)及びその水分析への応用に関する基礎研究"], "weko_shared_id": -1}
超音波発光(ソノルミネッセンス)及びその水分析への応用に関する基礎研究
http://hdl.handle.net/10098/3332
http://hdl.handle.net/10098/33324b1366d4-7676-4b0f-b861-c3ec62f8d02b
名前 / ファイル | ライセンス | アクション |
---|---|---|
AN00215401-047-01-001.pdf (328.3 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-06-02 | |||||
タイトル | ||||||
タイトル | 超音波発光(ソノルミネッセンス)及びその水分析への応用に関する基礎研究 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Basic Study on the Sonoluminescence Phenomenon and Its Potential Application to Water Analysis | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Sonoluminescence | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Luminol | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | UItrasonic Cleaner | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | UItrasonic Homogenizer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Water Analysis | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
神埼, 幸輔
× 神埼, 幸輔× 呉, 行正× KANZAKI, Kousuke× WU, Xing-Zheng |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This research aims at exploring possible application of the sonoluminescence phenomenon to water analysis. Experimental setups for measurement of sonoluminescence of water or sonic chemiluminescence of luminol aqueous solution have been prepared. Firstly an ultrasonic cleaner was used as a source of sonic wave. A glass tube used as a cell was directly immersed into water in the cleaner. Sonoluminescence of water from the cell was detected by a photomultiplier tube (PMT) . Although sonoluminescence of water was very weak, sonic chemiluminescence of luminol solution was strong enough in the ultrasonic cleaner. Secondly, an ultrasonic homogenizer was used as the sonic wave source. A micro tip of the ultrasonic homogenizer was directly immersed into a cell, which was a glass tube with internal diameter of I cm. Strong and stable sonoluminescence of water was observed. Experimental factors affecting the sonic chemiluminescence of luminol and sonoluminescence of water have been examined. The potential application of the sonoluminescence was also discussed. | |||||
書誌情報 |
福井大学工学部研究報告 巻 47, 号 1, p. 1-7, 発行日 1999-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 4298373 | |||||
書誌レコードID | ||||||
識別子タイプ | NCID | |||||
関連識別子 | TD00004606 |