WEKO3
アイテム
{"_buckets": {"deposit": "4d066839-8e36-46d2-9216-1e285f9adaca"}, "_deposit": {"created_by": 1, "id": "21697", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "21697"}, "status": "published"}, "_oai": {"id": "oai:u-fukui.repo.nii.ac.jp:00021697", "sets": ["2264"]}, "author_link": ["62466", "62468", "62467"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1978-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "135", "bibliographicPageStart": "131", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "福井大学工学部研究報告"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "For the purpose of estimating the ventilating pressure in tunnels, atmospheric pressure of several locations in tunnels were measured by using a well-known barometer. But there are some difficulties in getting the accuracy of measurements. This paper deals with a measuring device of atmospheric pressure based on variation of boilib points of water. Such devices already have been studied, but never have we heard of its utilization. It is the reason why the temperature of boiling points is depended on the position where the temperature sensor is placed. So the authors made an attempt to use the float on which the temperature sensor is attached. In this way, temperature of the sensor could be kept more steable than that without the float. As the results, it was found that the variation of the atmospheric pressure, about 2 mmAq, could be measured by using this device.", "subitem_description_type": "Abstract"}]}, "item_10002_relation_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "TD00004067", "subitem_relation_type_select": "NCID"}}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "4298373", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "DANNO, Masaru"}], "nameIdentifiers": [{"nameIdentifier": "62466", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TAKIMOTO, Masaki"}], "nameIdentifiers": [{"nameIdentifier": "62467", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HAYASHI, Shoji"}], "nameIdentifiers": [{"nameIdentifier": "62468", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-08-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AN00215401-026-01-014.pdf", "filesize": [{"value": "268.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 268200.0, "url": {"label": "AN00215401-026-01-014.pdf", "url": "https://u-fukui.repo.nii.ac.jp/record/21697/files/AN00215401-026-01-014.pdf"}, "version_id": "770ceb41-2ede-48be-a1a6-7642c9d96d11"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ATMOSPHERIC PRESSURE MEASUREMENT BY MEANS OF VARIATION OF BOILING POINT OF WATER", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ATMOSPHERIC PRESSURE MEASUREMENT BY MEANS OF VARIATION OF BOILING POINT OF WATER"}]}, "item_type_id": "10002", "owner": "1", "path": ["2264"], "permalink_uri": "http://hdl.handle.net/10098/4445", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-11-09"}, "publish_date": "2011-11-09", "publish_status": "0", "recid": "21697", "relation": {}, "relation_version_is_last": true, "title": ["ATMOSPHERIC PRESSURE MEASUREMENT BY MEANS OF VARIATION OF BOILING POINT OF WATER"], "weko_shared_id": -1}
ATMOSPHERIC PRESSURE MEASUREMENT BY MEANS OF VARIATION OF BOILING POINT OF WATER
http://hdl.handle.net/10098/4445
http://hdl.handle.net/10098/44453ab4f64e-354e-4cf6-b466-3b009ccf417e
名前 / ファイル | ライセンス | アクション |
---|---|---|
AN00215401-026-01-014.pdf (268.2 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-11-09 | |||||
タイトル | ||||||
タイトル | ATMOSPHERIC PRESSURE MEASUREMENT BY MEANS OF VARIATION OF BOILING POINT OF WATER | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
DANNO, Masaru
× DANNO, Masaru× TAKIMOTO, Masaki× HAYASHI, Shoji |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | For the purpose of estimating the ventilating pressure in tunnels, atmospheric pressure of several locations in tunnels were measured by using a well-known barometer. But there are some difficulties in getting the accuracy of measurements. This paper deals with a measuring device of atmospheric pressure based on variation of boilib points of water. Such devices already have been studied, but never have we heard of its utilization. It is the reason why the temperature of boiling points is depended on the position where the temperature sensor is placed. So the authors made an attempt to use the float on which the temperature sensor is attached. In this way, temperature of the sensor could be kept more steable than that without the float. As the results, it was found that the variation of the atmospheric pressure, about 2 mmAq, could be measured by using this device. | |||||
書誌情報 |
福井大学工学部研究報告 巻 26, 号 1, p. 131-135, 発行日 1978-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 4298373 | |||||
書誌レコードID | ||||||
識別子タイプ | NCID | |||||
関連識別子 | TD00004067 |