An all-in-one point-of-care testing device for multiplexed detection of respiratory infections

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

An all-in-one point-of-care testing device for multiplexed detection of respiratory infections

Mostrar el registro completo del ítem

Teixeira, W.; Pallás-Tamarit, Y.; Juste-Dolz, AM.; Sena-Torralba, A.; Gozalbo-Rovira, R.; Rodríguez-Díaz, J.; Navarro, D.... (2022). An all-in-one point-of-care testing device for multiplexed detection of respiratory infections. Biosensors and Bioelectronics. 213:1-7. https://doi.org/10.1016/j.bios.2022.114454

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/192049

Ficheros en el ítem

Metadatos del ítem

Título: An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
Autor: Teixeira, William Pallás-Tamarit, Yeray Juste-Dolz, Augusto Miguel Sena-Torralba, Amadeo Gozalbo-Rovira, Roberto Rodríguez-Díaz, Jesús Navarro, David Carrascosa Rubio, Javier Giménez-Romero, David Maquieira Catala, Angel Morais, Sergi
Entidad UPV: Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería Agronómica y del Medio Natural - Escola Tècnica Superior d'Enginyeria Agronòmica i del Medi Natural
Fecha difusión:
Fecha de fin de embargo: 2024-06-08
Resumen:
[EN] The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several ...[+]
Palabras clave: COVID-19 , SARS-CoV-2 , Influenza , Adenovirus , Respiratory syncytial virus , Microfluidics , Immunoassay
Derechos de uso: Embargado
Fuente:
Biosensors and Bioelectronics. (issn: 0956-5663 )
DOI: 10.1016/j.bios.2022.114454
Editorial:
Elsevier
Versión del editor: https://doi.org/10.1016/j.bios.2022.114454
Código del Proyecto:
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2019-110713RB-I00/ES/HACIA EL BIOSENSADO HOLOGRAFICO AVANZADO/
info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//COVID-19%2F5//ADAPTACION Y VALIDACION DE SISTEMAS BIOSENSORES CON TRANSDUCCIÓN OPTICA-CD Y VISCOELASTICA-QCM PARA LA DETECCION DE SARS/
info:eu-repo/grantAgreement/UPV//FPI 2017/
info:eu-repo/grantAgreement/UPV//PAID-19-01-06/
info:eu-repo/grantAgreement/GVA//PROMETEO%2F2020%2F094//HOLOGRAFÍA. UNA VIA PARA AFRONTAR NUEVOS RETOS EN BIOSENSADO/
Agradecimientos:
W. T and A. J-D acknowledge the financial support for the Ph.D. studies (PAID-19-01-06 and FPI-UPV 2017 grants, respectively). S.M awards grant PID2019-110713RB-I00 funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A ...[+]
Tipo: Artículo

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem