Título: | Monitoring the thermal-hygrometric conditions induced by traditional heating systems in a historic Spanish church (12th-16th C) |
Autor: | Varas, María José CSIC ORCID; Martínez-Garrido, M. I. CSIC ORCID; Fort González, Rafael CSIC ORCID | Palabras clave: | Thermal–hygrometric efficiency Traditional heating systems Heating church Monitoring strategy |
Fecha de publicación: | 21-feb-2014 | Editor: | Elsevier | Citación: | Energy and Buildings, 75: 119- 132 (2014) | Resumen: | Most historic churches are characterised by low thermal efficiency due primarily to their architectural design and the traditional materials used in their construction. Heating the huge volumes of air involved may be more or less effective depending on the HVAC system used. Up until very recently, traditional heating has been the system of choice in Spanish churches. The present study analysed the parish church at Talamanca de Jarama (a village on the outskirts of Madrid), where the forced hot-air system was found to induce wide fluctuations in indoor thermal-hygrometric (T/RH) conditions, in turn translating into the temporal and horizontal stratification of temperature and relative humidity. As a result, the thermal comfort sought for parishioners is not reached, for the air remains cold at pew height while heat accumulates in the upper area of the church. A three-dimensional sensor network was designed to monitor these conditions. Suspended from helium balloons, the sensors could record the indoor air temperature and humidity without causing any damage whatsoever to church property. © 2014 Elsevier B.V. All rights reserved. | Versión del editor: | http://dx.doi.org/10.1016/j.enbuild.2014.01.049 | URI: | http://hdl.handle.net/10261/118094 | DOI: | 10.1016/j.enbuild.2014.01.049 | Identificadores: | doi: 10.1016/j.enbuild.2014.01.049 issn: 0378-7788 |
Aparece en las colecciones: | (IGEO) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
EB_2015_Varas et al_Monitoring the thermal.pdf | 334 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
55
checked on 19-abr-2024
WEB OF SCIENCETM
Citations
51
checked on 27-feb-2024
Page view(s)
329
checked on 23-abr-2024
Download(s)
384
checked on 23-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.