Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/123015
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Beam tracking with micromegas & wire chambers in secondary electron detection configuration

AutorVoštinar, M.; Fernández-Martínez, Begoña CSIC ORCID; Álvarez, M. A. G. CSIC
Fecha de publicación2013
EditorInstitute of Physics Publishing
CitaciónJournal of Instrumentation 8: C12023 (2013)
ResumenThe focal plane of S3 (Super Separator Spectrometer), a new experimental area of SPIRAL2 at GANIL, will be used for identification of nuclei, and requires the reconstruction of their trajectories and velocities by the Time Of Flight (TOF) method. Classical tracking detectors used in-beam would generate a lot of angular and energy straggling due to their thickness. One solution is the use of a SED (Secondary Electron Detection), which consists of a thin emissive foil in beam coupled to a low pressure gaseous detector out of the beam, for the detection of secondary electrons ejected from the foil. Moreover, this type of detector can be used for classical beam tracking at low energies, or for example at NFS (GANIL) for the FALSTAFF experiment for the reconstruction of fission fragments trajectories. Several low pressure gaseous detectors such as wire chambers and Micromegas have been constructed and tested since 2008. High counting rate capabilities and good time resolution obtained in previous tests motivated the construction of a new real-size 2D prototype wire chamber and a 2D bulk Micromegas at low pressure. For the first time, spatial resolution of the Micromegas at low pressure (below 20 mbar) in the SED configuration was measured. Different tests have been performed in order to characterize time and spatial properties of both prototypes, giving spatial resolution in the horizontal (X) direction of 0.90(0.02) mm FWHM for the real size prototype and 0.72(0.08) mm FWHM for Micromegas, and a time resolution of ~ 110(25) ps for the real size prototype.
DescripciónTrabajo presentado a la: "3rd International Conference on Micro Pattern Gaseous Detectors (MPGD2013)", celebrada en Zaragoza (España) del 1 al 4 de julio de 2013.-- et al.
URIhttp://hdl.handle.net/10261/123015
DOI10.1088/1748-0221/8/12/C12023
Identificadoresdoi: 10.1088/1748-0221/8/12/C12023
e-issn: 1748-0221
Aparece en las colecciones: (CNA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

2
checked on 17-abr-2024

WEB OF SCIENCETM
Citations

2
checked on 20-feb-2024

Page view(s)

288
checked on 23-abr-2024

Download(s)

172
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.