Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/124918
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Resolving the octant of theta(23) with T2K and NOvA

AutorAgarwalla, Sanjib Kumar CSIC ORCID; Prakash, Suprabh; Sankar, S. Uma
Palabras claveNeutrino Physics
CP violation
Beyond Standard Model
Fecha de publicación1-jul-2013
EditorSpringer Nature
CitaciónJournal of High Energy Physics 07 (7): 131 - 24 (2013)
ResumenPreliminary results of MINOS experiment indicate that theta(23) is not maximal. Global fits to world neutrino data suggest two nearly degenerate solutions for theta(23): one in the lower octant (LO: theta(23) < 45 degrees) and the other in the higher octant (HO: theta(23) > 45 degrees). v(mu) -> v(e) oscillations in superbeam experiments are sensitive to the octant and are capable of resolving this degeneracy. We study the prospects of this resolution by the current T2K and upcoming NOvA experiments. Because of the hierarchy-delta(CP) degeneracy and the octant delta(CP) degeneracy, the impact of hierarchy on octant resolution has to be taken into account. As in the case of hierarchy determination, there exist favorable (unfavorable) values of delta(CP) for which octant resolution is easy (challenging). However, for octant resolution the unfavorable delta(CP) values of the neutrino data are favorable for the anti-neutrino data and vice-verse. This is in contrast to the case of hierarchy determination. In this paper, we compute the combined sensitivity of T2K and NOvA to resolve the octant ambiguity. If sin(2)theta(23) - 0.41, then NOvA can rule out all the values of theta(23) in HO at 2 sigma C.L., irrespective of the hierarchy and delta(CP). Addition of T2K data improves the octant sensitivity. If T2K were to have equal neutrino and anti-neutrino runs of 2.5 years each, a 2 sigma resolution of the octant becomes possible provided sin(2) theta(23) <= 0.43 or >= 0.58 for any value of delta(CP).
Versión del editorhttp://dx.doi.org/10.1007/JHEP07(2013)131
URIhttp://hdl.handle.net/10261/124918
DOI10.1007/JHEP07(2013)131
ISSN1029-8479
E-ISSN1029-8479
Aparece en las colecciones: (IFIC) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Resolving the octant.pdf944,39 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

54
checked on 12-abr-2024

WEB OF SCIENCETM
Citations

62
checked on 28-feb-2024

Page view(s)

203
checked on 17-abr-2024

Download(s)

175
checked on 17-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.