Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/149983
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Comparison of samplers for the biological characterization of the sea surface microlayer

AutorAgogué, Hélène; Casamayor, Emilio O. CSIC ORCID ; Joux, Fabien; Obernosterer, Ingrid; Dupuy, Christine; Lantoine, François; Català, P.; Weinbauer, Markus G.; Reinthaler, Thomas; Herndl, Gerhard J.; Lebaron, Philippe
Fecha de publicación2004
EditorAssociation for the Sciences of Limnology and Oceanography
CitaciónLimnology and Oceanography : methods 2 : 213-225 (2004)
ResumenThe surface film of the hydrosphere covers more than 70% of the world’s surface. The sea surface microlayer (SML) or “skin” of the ocean is a sink for natural and anthropogenic material originating from the atmosphere and the water column. Organisms living in this SML are called “neuston.” Our knowledge of the biology of the SML is still in its infancy. Research of the sea surface microlayer requires the use of appropriate sampling techniques and strategies, and the question of what is the most suitable device has not yet been answered. In the present study, we have compared the efficiency of the Harvey glass plate (GP) and the Garrett metal screen (MS) to analyze a wide range of microbiological parameters in SML samples collected at two coastal stations in the NW Mediterranean Sea. Two types of membranes (Teflon and polycarbonate) were also used to collect bacterioneuston. The MS was the most appropriate technique for most biological parameters providing higher enrichment factors as compared to the GP and, therefore, the highest enrichment factors compared with underlying waters (UW). Control experiments with UW demonstrated that the enrichment reported for the MS was not biased by any selectivity of the sampler itself. Therefore, we recommend the use of the MS when the aim is to compare different biological parameters. In contrast, there is clear evidence that hydrophobic and hydrophilic membranes have an important drawback and should not be used for quantification purposes.
DescripciónEste artículo contiene 15 páginas, 3 figuras, 4 tablas.
Versión del editorhttp://dx.doi.org/10.4319/lom.2004.2.213
URIhttp://hdl.handle.net/10261/149983
DOI10.4319/lom.2004.2.213
ISSN1541-5856
Aparece en las colecciones: (CEAB) Artículos

Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

93
checked on 20-abr-2024

WEB OF SCIENCETM
Citations

91
checked on 22-feb-2024

Page view(s)

270
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.