Título

Intercomparison of a portable and two stationary mobility particle sizers for nanoscale aerosol measurements

AutorFonseca, Ana Sofía CSIC ORCID; Viana, Mar CSIC ORCID ; Alastuey, Andrés CSIC ORCID; Querol, Xavier CSIC ORCID ; Kaminski, H.; Todea, M.; Monz, C.; Asbach, C.
Fecha de publicación20-abr-2016
EditorTaylor & Francis
CitaciónAerosol Science and Technology 50(7): 653-668
ResumenDuring occupational exposure studies, the use of conventional scanning mobility particle sizers (SMPS) provides high quality data but may convey transport and application limitations. New instruments aiming to overcome these limitations are being currently developed. The purpose of the present study was to compare the performance of the novel portable NanoScan SMPS TSI 3910 with that of two stationary SMPS instruments and one ultrafine condensation particle counter (UCPC) in a controlled atmosphere and for different particle types and concentrations. The results show that NanoScan tends to overestimate particle number concentrations with regard to the UCPC, particularly for agglomerated particles (ZnO, spark generated soot and diesel soot particles) with relative differences >20%. The best agreements between the internal reference values and measured number concentrations were obtained when measuring compact and spherical particles (NaCl and DEHS particles). With regard to particle diameter (modal size), results from NanoScan were comparable < [± 20%] to those measured by SMPSs for most of the aerosols measured. The findings of this study show that mobility particle sizers using unipolar and bipolar charging may be affected differently by particle size, morphologies, particle composition and concentration. While the sizing accuracy of the NanoScan SMPS was mostly within ±25%, it may miscount total particle number concentration by more than 50% (especially for agglomerated particles), thus making it unsuitable for occupational exposure assessments where high degree of accuracy is required (e.g., in tier 3). However, can be a useful instrument to obtain an estimate of the aerosol size distribution in indoor and workplace air, e.g., in tier 2.
Versión del editorhttp://dx.doi.org/10.1080/02786826.2016.1174329
URIhttp://hdl.handle.net/10261/157420
DOI10.1080/02786826.2016.1174329
ISSN0278-6826
Aparece en las colecciones: (IDAEA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Intercomparison of a portable and two stationary.pdf1,4 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

27
checked on 19-mar-2024

WEB OF SCIENCETM
Citations

27
checked on 28-feb-2024

Page view(s)

264
checked on 27-mar-2024

Download(s)

287
checked on 27-mar-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons