Título

A flow immunoassay for alkylphenol ethoxylate surfactants and their metabolites—questions associated with cross-reactivity, matrix effects, and validation by chromatographic techniques

AutorBadea, Mihaela; Nistor, Catalin; Goda, Yasuhiro; Fujimoto, Shigeru; Dosho, Shin; Danet, Andrei; Barceló, Damià CSIC ORCID; Ventura, Francesc; Emnéus, Jenny
Palabras claveEnzyme flow injection immunoassay (EFIIA)
Alkylphenolethoxylate (APEO)
Liquid chromatography–mass spectrometry (LC-MS)
Fecha de publicación11-jun-2003
EditorRoyal Society of Chemistry (UK)
CitaciónThe Analyst 128(7): 849-856 (2003)
ResumenThis paper describes the application and evaluation of a competitive enzyme flow injection immunoassay (EFIIA) for screening of alkylphenol ethoxylate (APEO) surfactants in different water samples based on a generic immunoassay system previously developed (see E. Burestedt, C Nistor, U. Schagerlöf and J. Emnéus, Anal. Chem., 2000, 72, 4171–4177). The detection limits for octylphenol ethoxylates (OPEOs), nonylphenol ethoxylates (NPEOs), and nonylphenol (NP) were 0.5 µg l–1, between 2 and 3 µg l–1, and 50 µg l–1, respectively, with a sample throughput of 6 h–1 (i.e., for triplicate analysis of each sample). Different OPEOs and NPEOs were highly cross-reactive within the assay, with sensitivities in the same order of magnitude for all the ethoxylates tested, thus the result obtained by the EFIIA method could be used as an alkylphenol ethoxylate index. No or minor matrix effects with recoveries between 70–120% for the reference analyte NPEO10 in tap, and surface water, and acceptable for rainwater, were observed. Influent and effluent surfactant containing wastewater samples were analysed by EFIIA, LC-MS, LC-Fluoresence (LC-FL), and a commercial microplate ELISA. High recoveries for different concentrations of APEO10 spiked into a 200 times diluted raw influent and effluent wastewater were achieved with the EFIIA method, however, the found APEO content of the same diluted wastewater samples, before spiking, could not be correlated directly to the chromatographic result by any of the immunoassays, and the possible reasons for this are discussed. The same trend of decreasing APEO content from influent to effluent wastewater could, however, be followed for all methods employed.
Descripción8 pages, 5 figures, 5 tables.-- Printed version published Jul 2003.-- Supporting iniformation available at: http://www.rsc.org/suppdata/an/b3/b302110f/
Versión del editorhttp://dx.doi.org/10.1039/b302110f
URIhttp://hdl.handle.net/10261/19775
DOI10.1039/b302110f
ISSN0003-2654
E-ISSN1364-5528
Aparece en las colecciones: (IDAEA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Badea_Mihaela_et_al.pdf114,74 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

11
checked on 17-abr-2024

WEB OF SCIENCETM
Citations

10
checked on 26-feb-2024

Page view(s)

360
checked on 23-abr-2024

Download(s)

378
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.