Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/207081
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Título: | Handheld probe for quantitative micro-elastography |
Autor: | Fang, Q.I.; Krajancich, B.; Chin, L.; Zilkens, R.; Curatolo, Andrea CSIC ORCID; Frewer, L.; Anstie, J.D.; Wijesinghe, P.; Hall, C.; Dessauvagie, B.F.; Latham, B.; Saunders, C.M.; Kennedy, B.F. | Fecha de publicación: | 16-jul-2019 | Editor: | Optical Society of America | Citación: | Biomedical Optics Express 10: 4034- 4049 (2019) | Resumen: | Optical coherence elastography (OCE) has been proposed for a range of clinical applications. However, the majority of these studies have been performed using bulky, lab-based imaging systems. A compact, handheld imaging probe would accelerate clinical translation, however, to date, this had been inhibited by the slow scan rates of compact devices and the motion artifact induced by the user’s hand. In this paper, we present a proof-of-concept, handheld quantitative micro-elastography (QME) probe capable of scanning a 6 × 6 × 1 mm volume of tissue in 3.4 seconds. This handheld probe is enabled by a novel QME acquisition protocol that incorporates a custom bidirectional scan pattern driving a microelectromechanical system (MEMS) scanner, synchronized with the sample deformation induced by an annular PZT actuator. The custom scan pattern reduces the total acquisition time and the time difference between B-scans used to generate displacement maps, minimizing the impact of motion artifact. We test the feasibility of the handheld QME probe on a tissue-mimicking silicone phantom, demonstrating comparable image quality to a bench-mounted setup. In addition, we present the first handheld QME scans performed on human breast tissue specimens. For each specimen, quantitative micro-elastograms are co-registered with, and validated by, histology, demonstrating the ability to distinguish stiff cancerous tissue from surrounding soft benign tissue. | Descripción: | 16 pags., 7 figs., 1 tab. | Versión del editor: | http://dx.doi.org/10.1364/BOE.10.004034 | URI: | http://hdl.handle.net/10261/207081 | DOI: | 10.1364/BOE.10.004034 | Identificadores: | doi: 10.1364/BOE.10.004034 issn: 2156-7085 |
Aparece en las colecciones: | (CFMAC-IO) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Handheld probe.pdf | 4,43 MB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
PubMed Central
Citations
9
checked on 05-abr-2024
SCOPUSTM
Citations
18
checked on 24-abr-2024
WEB OF SCIENCETM
Citations
17
checked on 28-feb-2024
Page view(s)
114
checked on 24-abr-2024
Download(s)
110
checked on 24-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
Artículos relacionados:
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.