Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/221782
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Neutron flux and spectrum in the dresden felsenkeller underground facility studied by moderated he 3 counters

AutorGrieger, M.; Hensel, T.; Agramunt, Jorge CSIC ORCID; Bemmerer, D.; Degering, D.; Dillmann, I.; Fraile, Luis M. ; Jordan, D.; Köster, U.; Marta, M.; Müller, S.E.; Szücs, T.; Tain, José Luis; Zuber, K.
Fecha de publicaciónjun-2020
EditorAmerican Physical Society
CitaciónPhysical Review D 101: 123027 (2020)
ResumenAmbient neutrons may cause significant background for underground experiments. Therefore, it is necessary to investigate their flux and energy spectrum in order to devise a proper shielding. Here, two sets of altogether ten moderated He3 neutron counters are used for a detailed study of the ambient neutron background in tunnel IV of the Felsenkeller facility, underground below 45 m of rock in Dresden/Germany. One of the moderators is lined with lead and thus sensitive to neutrons of energies higher than 10 MeV. For each He3 counter moderator assembly, the energy-dependent neutron sensitivity was calculated with the FLUKA code. The count rates of the ten detectors were then fitted with the MAXED and GRAVEL packages. As a result, both the neutron energy spectrum from 10-9 to 300 MeV and the flux integrated over the same energy range were determined experimentally. The data show that at a given depth, both the flux and the spectrum vary significantly depending on local conditions. Energy-integrated fluxes of (0.61±0.05), (1.96±0.15), and (4.6±0.4)×10-4 cm-2 s-1, respectively, are measured for three sites within Felsenkeller tunnel IV which have similar muon flux but different shielding wall configurations. The integrated neutron flux data and the obtained spectra for the three sites are matched reasonably well by FLUKA Monte Carlo calculations that are based on the known muon flux and composition of the measurement room walls.
Versión del editorhttp://dx.doi.org/10.1103/PhysRevD.101.123027
URIhttp://hdl.handle.net/10261/221782
DOI10.1103/PhysRevD.101.123027
Identificadoresdoi: 10.1103/PhysRevD.101.123027
issn:: 2470-0029
Aparece en las colecciones: (IFIC) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
66_Agramunt_Neutron.pdf738,67 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

11
checked on 09-abr-2024

WEB OF SCIENCETM
Citations

7
checked on 27-feb-2024

Page view(s)

91
checked on 16-abr-2024

Download(s)

313
checked on 16-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons