Evaluation of mechanical properties and biological response of an alumina-forming Ni-free ferritic alloy

AutorGonzález-Carrasco, José Luis CSIC ORCID CVN ; Ciapetti, G.; Montealegre, M. A.; Pagani, S.; Chao, Jesús CSIC; Baldini, N.
Fecha de publicación2005
EditorElsevier
CitaciónBiomaterials 26: 3861-3871 (2005)
ResumenPM 2000 is a Ni-free oxide dispersion strengthened Fe-20Cr-5Al alloy able to develop a fine, dense and tightly adherent α-alumina scale during high-temperature oxidation. Despite the high temperature involved during thermal oxidation (1100°C), microstructural changes in the candidate material, a hot rolled product, hardly occurs. Consequently, the good mechanical properties of the as-received material are not significantly affected. Moreover, due to the high compressive residual stresses at the alumina scale, an increase in the fatigue limit from 500 to 530 MPa is observed. Such stresses also account for the high capability of the coating/metal system to withstand more than 1% tensile deformation without cracking. The biocompatibility of the alloy was assessed in comparison to commercial alumina. Saos-2 osteoblast-like cells were either challenged with PM 2000 particles, or seeded onto PM 2000 (with and without scale) solid samples. Viability, growth, and ALP release from cells were assessed after 3 or 7 days, while mineralization was checked at 18 days. This study has demonstrated that PM 2000 with and without scale are capable of supporting in vitro growth and function of osteoblast-like cells over a period of 18 days. Results from this study suggest that the resulting alumina/alloy system combines the good mechanical properties of the alloy with the superior biocompatibility of the α-alumina, for which there is very good clinical experience. © 2004 Elsevier Ltd. All rights reserved.
URIhttp://hdl.handle.net/10261/76775
DOI10.1016/j.biomaterials.2004.09.058
Identificadoresdoi: 10.1016/j.biomaterials.2004.09.058
issn: 0142-9612
Aparece en las colecciones: (CENIM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

24
checked on 08-abr-2024

WEB OF SCIENCETM
Citations

21
checked on 27-feb-2024

Page view(s)

261
checked on 17-abr-2024

Download(s)

88
checked on 17-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.