University of Limerick
Browse
Cunnane_2018_Characterisation.pdf (1.52 MB)

Characterisation of human urethral rupture thresholds for urinary catheter inflation related injuries

Download (1.52 MB)
journal contribution
posted on 2018-05-04, 08:14 authored by Niall Francis Davis, Eoghan M. Cunnane, Rory Mooney, J. Hess, Michael T. Walsh
Data on urethral catheter related injuries is sparse. In this study we aimed to characterise urethral diametric strain and urinary catheter inflation pressure thresholds that precede human urethral trauma during urethral catheterisation (UC). Human urethras were obtained from patients undergoing male to female gender reassignment surgery [(n = 9; age 40 ± 13.13 (range: 18–58)) years]. 12Fr urinary catheters were secured in the bulbar urethra and the catheter's anchoring balloon was inflated with a syringe pump apparatus. Urethral diametric strain and balloon pressure were characterised with video extensometry and a pressure transducer respectively. Immunohistochemistry, Masson's trichrome and Verhoeff-Van Gieson stains evaluated urethral trauma microscopically. Morphological characterisation of the urethral lumen was performed by examining non-traumatised histological sections of urethra and recording luminal area, perimeter and major/minor axis length. Tearing (n = 3) and rupture (n = 3) of the urethra were observed following catheter balloon inflation. The threshold for human urethral rupture occurred at an external urethral diametric strain ≥ 27% and balloon inflation pressure ≥ 120kPa. Significant relationships were identified between urethral wall thickness and the level of trauma induced during catheter balloon inflation (p = 0.001) and between the pressure required to inflate the catheter balloon and the length of the major axis of the urethral lumen (p = 0.004). Ruptured urethras demonstrated complete transection of collagen, elastin and muscle fibres. In conclusion, urethral rupture occurs at an external urethral diametric strain ≥ 27% or with balloon inflation pressures ≥ 120 kPa. Incorporation of these parameters may be useful for designing a safety mechanism for preventing catheter inflation related urethral injuries.

Funding

Study on Aerodynamic Characteristics Control of Slender Body Using Active Flow Control Technique

Japan Society for the Promotion of Science

Find out more...

History

Publication

Journal of the Mechanical Behavior of Biomedical Materials;83, pp. 102-107

Publisher

Elsevier

Note

peer-reviewed

Other Funding information

ERC, European Union (EU), Horizon 2020

Rights

This is the author’s version of a work that was accepted for publication in Journal of the Mechanical Behavior of Biomedical Materials . Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in

Language

English

Usage metrics

    University of Limerick

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC