Publications

Detailed Information

Effects of anodized oxidation or turned implants on bone healing after using conventional drilling or trabecular compaction technique: histomorphometric analysis and RFA

Cited 20 time in Web of Science Cited 22 time in Scopus
Authors

Kim, Shin Koo; Lee, Han Na; Choi, Yong Chang; Heo, Seong-Joo; Lee, Cheol Won; Choie, Mok Kyun

Issue Date
2006-12
Publisher
Wiley-Blackwell
Citation
Clin Oral Implants Res 17(6):644-560
Keywords
anodic oxidationosseointegrationosteotome techniquesoft bonetrabecular compaction
Abstract
Abstract
Objectives: The aim of this study was to compare the bone healing characteristics adjacent
to anodic oxidation and turned surfaces after implant installation using the trabecular
compaction technique or the conventional drilling technique in the soft bone area.
Material and methods: A total of 72 implants (36 anodic oxidation surface and 36 turned
surface implants) were inserted into the distal end of the femur head of 12 dogs by two
different surgical techniques. There were four experimental groups: (1) DT group;
drillingþturned, (2) DO group; drillingþoxidation, (3) CT group; compactionþturned,
and (4) CO group; compactionþoxidation. The resonance frequency was measured and six
specimens/treatment group were obtained at 0, 3 and 8 weeks, postoperatively.
Undecalcified ground sections were prepared for histologic and histomorphometric
examinations.
Results: At week 0, the trabecular compaction groups showed a higher bone to implant
contact ratio (BIC) than the conventional drilling groups, regardless of surface types. The CT
group showed a higher implant stability quotient (ISQ) than the DT group. At week 3, the
oxidation groups showed a higher BIC than the turned groups regardless of the surgical
technique used. The CO group showed higher ISQ than the CT group. At week 8, there was
no statistically significant difference in BIC and ISQ between the groups.
Conclusions: Surgical technique and implant surface state have an effect on the initial
bone response to two-stage implants inserted into trabecular bone regions.
ISSN
0905-7161
Language
English
URI
https://hdl.handle.net/10371/69603
DOI
https://doi.org/10.1111/j.1600-0501.2006.01285.x
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share