Title: A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements : theory and simulation study
Authors: Feng, DD
Wong, KP
Wu, CM
Siu, WC 
Issue Date: Dec-1997
Source: IEEE transactions on information technology in biomedicine, Dec. 1997, v. 1, no. 4, p. 243-254
Abstract: Positron emission tomography (PET) is an important tool for enabling quantification of human brain function. However, quantitative studies using tracer kinetic modeling require the measurement of the tracer time-activity curve in plasma (PTAC) as the model input function. It is widely believed that the insertion of arterial lines and the subsequent collection and processing of the biomedical signal sampled from the arterial blood are not compatible with the practice of clinical PET, as it is invasive and exposes personnel to the risks associated with the handling of patient blood and radiation dose. Therefore, it is of interest to develop practical noninvasive measurement techniques for tracer kinetic modeling with PET. In this paper, a technique is proposed to extract the input function together with the physiological parameters from the brain dynamic images alone. The identifiability of this method is tested rigorously by using Monte Carlo simulation. The results show that the proposed method is able to quantify all the required parameters by using the information obtained from two or more regions of interest (ROI's) with very different dynamics in the PET dynamic images. There is no significant improvement in parameter estimation for the local cerebral metabolic rate of glucose (LCMRGlc) if the number of ROI's are more than three. The proposed method can provide very reliable estimation of LCMRGlc, which is our primary interest in this study.
Keywords: Modeling
Noninvasive measurement
Positron emission tomography (PET)
Simulation
Publisher: Institute of Electrical and Electronics Engineers
Journal: IEEE transactions on information technology in biomedicine 
ISSN: 1089-7771
DOI: 10.1109/4233.681168
Rights: © 1997 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Feng_et_al_Extracting_Physiological_Parameters.pdf366.55 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

101
Last Week
2
Last month
Citations as of Apr 14, 2024

Downloads

249
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

138
Last Week
0
Last month
0
Citations as of Apr 19, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.