Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/76418
PIRA download icon_1.1View/Download Full Text
Title: Accuracy and reliability of cetacean cranial measurements using computed tomography three dimensional volume rendered images
Authors: Yuen, AHL
Tsui, HCL
Kot, BCW 
Issue Date: 2017
Source: PLoS one, 2017, v. 12, no. 3, e0174215
Abstract: Computed tomography (CT) has become more readily available for post-mortem examination, offering an alternative to cetacean cranial measurements obtained manually. Measurement error may result in possible variation in cranial morphometric analysis. This study aimed to evaluate the accuracy and reliability of cetacean cranial measurements obtained by CT three-dimensional volume rendered images (3DVRI). CT scans of 9 stranded cetaceans were performed. The acquired images were reconstructed using bone reconstruction algorithms. The reconstructed crania obtained by 3DVRI were visualized after excluding other body structures. Accuracy of cranial measurements obtained by CT 3DVRI was evaluated by comparing with that obtained by manual approach as standard of reference. Reproducibility and repeatability of cranial measurements obtained by CT 3DVRI were evaluated using intraclass correlation coefficient (ICC). The results demonstrated that cranial measurements obtained by CT 3DVRI yielded high accuracy (88.05%-99.64%). High reproducibility (ICC ranged from 0.897 to 1.000) and repeatability (ICC ranged from 0.919 to 1.000 for operator 1 and ICC range from 0.768 to 1.000 for operator 2) were observed in cranial measurements obtained by CT 3DVRI. Therefore, cranial measurements obtained by CT 3DVRI could be considered as virtual alternative to conventional manual approach. This may help the development of a normative reference for current cranial maturity and discriminant analysis studies in cetaceans.
Publisher: Public Library of Science
Journal: PLoS one 
EISSN: 1932-6203
DOI: 10.1371/journal.pone.0174215
Rights: © 2017 Yuen et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
The following publication: Yuen AHL, Tsui HCL, Kot BCW (2017) Accuracy and reliability of cetacean cranial measurements using computed tomography three dimensional volume rendered images. PLoS ONE 12(3): e0174215 is available at https://doi.org/10.1371/journal.pone.0174215
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Yuen_Accuracy_reliability_cetacean.pdf1.11 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

138
Last Week
0
Last month
Citations as of Apr 21, 2024

Downloads

101
Citations as of Apr 21, 2024

SCOPUSTM   
Citations

12
Last Week
0
Last month
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

12
Last Week
0
Last month
Citations as of Apr 25, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.