Within the framework of the Work Package DIV 1 – “Divertor Cassette Design and Integration” of the EUROfusion action, a research campaign has been jointly carried out by ENEA and University of Palermo to investigate the thermal-hydraulic performances of the DEMO divertor cassette cooling system. A comparative evaluation study has been performed considering three different options for the cooling circuit layout of the divertor Plasma Facing Components (PFCs). The potential improvement in the thermal-hydraulic performance of the cooling system, to be achieved by modifying cooling circuit layout, has been also assessed and discussed in terms of optimization strategy. The research activity has been carried out following a theoretical-computational approach based on the finite volume method and adopting a qualified Computational Fluid-Dynamic (CFD) code. Results obtained are reported and critically discussed.

Di Maio, P., Garitta, S., You, J., Mazzone, G., Vallone, E. (2017). Thermal-hydraulic behaviour of the DEMO divertor plasma facing components cooling circuit. FUSION ENGINEERING AND DESIGN, 124, 415-419 [10.1016/j.fusengdes.2017.02.025].

Thermal-hydraulic behaviour of the DEMO divertor plasma facing components cooling circuit

Di Maio, P. A.;Garitta, S.
;
Vallone, E.
2017-01-01

Abstract

Within the framework of the Work Package DIV 1 – “Divertor Cassette Design and Integration” of the EUROfusion action, a research campaign has been jointly carried out by ENEA and University of Palermo to investigate the thermal-hydraulic performances of the DEMO divertor cassette cooling system. A comparative evaluation study has been performed considering three different options for the cooling circuit layout of the divertor Plasma Facing Components (PFCs). The potential improvement in the thermal-hydraulic performance of the cooling system, to be achieved by modifying cooling circuit layout, has been also assessed and discussed in terms of optimization strategy. The research activity has been carried out following a theoretical-computational approach based on the finite volume method and adopting a qualified Computational Fluid-Dynamic (CFD) code. Results obtained are reported and critically discussed.
2017
Settore ING-IND/19 - Impianti Nucleari
Di Maio, P., Garitta, S., You, J., Mazzone, G., Vallone, E. (2017). Thermal-hydraulic behaviour of the DEMO divertor plasma facing components cooling circuit. FUSION ENGINEERING AND DESIGN, 124, 415-419 [10.1016/j.fusengdes.2017.02.025].
File in questo prodotto:
File Dimensione Formato  
RI-52.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/274796
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact