This paper shows the first results of a study aimed at monitoring the deformations of the dome of the Massimo Theatre in Palermo caused by thermal dilatations, with the use of topographic and photogrammetric integrated techniques. Particularly, two robotic total stations and high precision digital photogrammetric systems were employed. In order to correlate the displacements of the rollers on which the steel structure of the dome rest with the thermal gradients, different thermal images were acquired by a thermal imaging camera. The main goal of the work was to compare the two techniques with reference to very small (submillimeter) deformation measurements. The obtained results show that the rollers are still working correctly. In fact, for a thermal gradient of 6 °C both topographic and photogrammetric techniques determined displacements in the order of 0.8 mm, according with the expected deformations of the theoretical model.

Dardanelli, G., Orlando, P., Villa, B. (2012). Comparison between topographic and photogrammetric techniques for deformation monitoring of the dome of the Massimo Theatre in Palermo. In FIG Working Week 2012 Proceedings (pp.1-15). Copenhagen : FIG.

Comparison between topographic and photogrammetric techniques for deformation monitoring of the dome of the Massimo Theatre in Palermo

DARDANELLI, Gino;ORLANDO, Pietro;VILLA, Benedetto
2012-01-01

Abstract

This paper shows the first results of a study aimed at monitoring the deformations of the dome of the Massimo Theatre in Palermo caused by thermal dilatations, with the use of topographic and photogrammetric integrated techniques. Particularly, two robotic total stations and high precision digital photogrammetric systems were employed. In order to correlate the displacements of the rollers on which the steel structure of the dome rest with the thermal gradients, different thermal images were acquired by a thermal imaging camera. The main goal of the work was to compare the two techniques with reference to very small (submillimeter) deformation measurements. The obtained results show that the rollers are still working correctly. In fact, for a thermal gradient of 6 °C both topographic and photogrammetric techniques determined displacements in the order of 0.8 mm, according with the expected deformations of the theoretical model.
Settore ICAR/06 - Topografia E Cartografia
7-mag-2012
FIG Working Week 2012
Roma
6-10 maggio 2012
2012
00
Dardanelli, G., Orlando, P., Villa, B. (2012). Comparison between topographic and photogrammetric techniques for deformation monitoring of the dome of the Massimo Theatre in Palermo. In FIG Working Week 2012 Proceedings (pp.1-15). Copenhagen : FIG.
Proceedings (atti dei congressi)
Dardanelli, G; Orlando, P; Villa, B
File in questo prodotto:
File Dimensione Formato  
Paper_no_5800.pdf

accesso aperto

Descrizione: Articolo
Dimensione 1.61 MB
Formato Adobe PDF
1.61 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.