Background - No information is available on the long-term results of radial artery (RA) grafts used as coronary artery bypass conduits. Methods and Results - In this report, we describe the long-term (105±9 months) angiographic results of a series of 90 consecutive patients in whom the RA was used as a coronary artery bypass conduit directly anastomosed to the ascending aorta. The long-term patency and perfect patency rates of the RA were 91.6% and 88%, respectively, versus 97.5% and 96.3% for internal thoracic artery grafts. The severity of stenosis of the target vessel clearly influenced long-term RA patency, whereas location of the target vessel and long-term use of calcium channel blockers did not influence angiographic results. Preserved endothelial function and absence of flow-limiting, fibrous, intimal hyperplasia were also documented. Conclusions - Ten years after surgery, RA grafts have excellent patency and perfect patency rates. Appropriate surgical technique and correct indication are the key factors for long-term RA patency.

Possati, G., Gaudino, M., Prati, F., Alessandrini, F., Trani, C., Glieca, F., Mazzari, M. A., Luciani, N., Schiavoni, G., Long-term results of the radial artery used for myocardial revascularization, <<CIRCULATION>>, 2003; 108 (11): 1350-1354. [doi:10.1161/01.CIR.0000087402.13786.D0] [http://hdl.handle.net/10807/157228]

Long-term results of the radial artery used for myocardial revascularization

Gaudino, M.;Prati, F.;Alessandrini, F.;Trani, C.;Glieca, F.;Luciani, N.;Schiavoni, G.
2003

Abstract

Background - No information is available on the long-term results of radial artery (RA) grafts used as coronary artery bypass conduits. Methods and Results - In this report, we describe the long-term (105±9 months) angiographic results of a series of 90 consecutive patients in whom the RA was used as a coronary artery bypass conduit directly anastomosed to the ascending aorta. The long-term patency and perfect patency rates of the RA were 91.6% and 88%, respectively, versus 97.5% and 96.3% for internal thoracic artery grafts. The severity of stenosis of the target vessel clearly influenced long-term RA patency, whereas location of the target vessel and long-term use of calcium channel blockers did not influence angiographic results. Preserved endothelial function and absence of flow-limiting, fibrous, intimal hyperplasia were also documented. Conclusions - Ten years after surgery, RA grafts have excellent patency and perfect patency rates. Appropriate surgical technique and correct indication are the key factors for long-term RA patency.
2003
Inglese
Possati, G., Gaudino, M., Prati, F., Alessandrini, F., Trani, C., Glieca, F., Mazzari, M. A., Luciani, N., Schiavoni, G., Long-term results of the radial artery used for myocardial revascularization, <<CIRCULATION>>, 2003; 108 (11): 1350-1354. [doi:10.1161/01.CIR.0000087402.13786.D0] [http://hdl.handle.net/10807/157228]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/157228
Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 193
  • ???jsp.display-item.citation.isi??? 173
social impact