Počet záznamů: 1  

Analysis of OJIP Chlorophyll Fluorescence Kinetics and Q(A) Reoxidation Kinetics by Direct Fast Imaging

  1. 1.
    0511085 - BC 2020 RIV US eng J - Článek v odborném periodiku
    Küpper, Hendrik - Benedikty, Z. - Morina, Filis - Andresen, Elisa - Mishra, Archana - Trtílek, M.
    Analysis of OJIP Chlorophyll Fluorescence Kinetics and Q(A) Reoxidation Kinetics by Direct Fast Imaging.
    Plant Physiology. Roč. 179, č. 2 (2019), s. 369-381. ISSN 0032-0889. E-ISSN 1532-2548
    Grant CEP: GA MŠMT EF15_003/0000336
    Institucionální podpora: RVO:60077344
    Klíčová slova: in-vivo * induction * stress
    Obor OECD: Biophysics
    Impakt faktor: 6.902, rok: 2019
    Způsob publikování: Open access
    http://www.plantphysiol.org/content/179/2/369

    Chlorophyll fluorescence kinetic analysis has become an important tool in basic and applied research on plant physiology and agronomy. While early systems recorded the integrated kinetics of a selected spot or plant, later systems enabled imaging of at least the slower parts of the kinetics (20-ms time resolution). For faster events, such as the rise from the basic dark-adapted fluorescence yield to the maximum (OJIP transient), or the fluorescence yield decrease during reoxidation of plastoquinone A after a saturating flash, integrative systems are used because of limiting speed of the available imaging systems. In our new macroscopic and microscopic systems, the OJIP or plastonique A reoxidation fluorescence transients are directly imaged using an ultrafast camera. The advantage of such systems compared to nonimaging measurements is the analysis of heterogeneity of measured parameters, for example between the photosynthetic tissue near the veins and the tissue further away from the veins. Further, in contrast to the pump-and-probe measurement, direct imaging allows for measuring the transition of the plant from the dark-acclimated to a light-acclimated state via a quenching analysis protocol in which every supersaturating flash is coupled to a measurement of the fast fluorescence rise. We show that pump-and-probe measurement of OJIP is prone to artifacts, which are eliminated with the direct measurement. The examples of applications shown here, zinc deficiency and cadmium toxicity, demonstrate that this novel imaging platform can be used for detection and analysis of a range of alterations of the electron flow around PSII.
    Trvalý link: http://hdl.handle.net/11104/0302011

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.