Wearable systems are gaining broad acceptance for monitoring physiological parameters in several medical applications. Among a number of approaches, smart textiles have attracted interest because they are comfortable and do not impair patients' movements. In this article, we aim at developing a smart textile for respiratory monitoring based on a piezoresistive sensing element. Firstly, the calibration curve of the system and its hysteresis have been investigated. Then, the proposed system has been assessed on 6 healthy subjects. The volunteers were invited to wear the system to monitor their breathing rate. The results of the calibration show a good mean sensitivity (i.e., approximately 0.11V·%-1); although the hysteresis is not negligible, the system can follow the cycles also at high rates (up to 36 cycle·min-1). The feasibility assessment on 6 volunteers (two trials for each one) shows that the proposed system can estimate with good accuracy the breathing rate. Indeed, the results obtained by the proposed system were compared with the ones collected with a spirometer, used as reference. Considering all the experiments, a mean percentage error was approximately 2%. In conclusion, the proposed system has several valuable features (e.g., the sensing element is lightweight, the sensitivity is high, and it is possible to develop comfortable smart textile); in addition, the promising performances considering both metrological properties and assessment on volunteers foster future tests focused on: i) the possibility of developing and system embedding several sensing elements, and ii) to develop a wireless acquisition system, to allow comfortable and long-term acquisition in both patients and during sport activities.

Wearable textile based on silver plated knitted sensor for respiratory rate monitoring

Saccomandi P.;Perego P.;Andreoni G.;Schena E.
2018-01-01

Abstract

Wearable systems are gaining broad acceptance for monitoring physiological parameters in several medical applications. Among a number of approaches, smart textiles have attracted interest because they are comfortable and do not impair patients' movements. In this article, we aim at developing a smart textile for respiratory monitoring based on a piezoresistive sensing element. Firstly, the calibration curve of the system and its hysteresis have been investigated. Then, the proposed system has been assessed on 6 healthy subjects. The volunteers were invited to wear the system to monitor their breathing rate. The results of the calibration show a good mean sensitivity (i.e., approximately 0.11V·%-1); although the hysteresis is not negligible, the system can follow the cycles also at high rates (up to 36 cycle·min-1). The feasibility assessment on 6 volunteers (two trials for each one) shows that the proposed system can estimate with good accuracy the breathing rate. Indeed, the results obtained by the proposed system were compared with the ones collected with a spirometer, used as reference. Considering all the experiments, a mean percentage error was approximately 2%. In conclusion, the proposed system has several valuable features (e.g., the sensing element is lightweight, the sensitivity is high, and it is possible to develop comfortable smart textile); in addition, the promising performances considering both metrological properties and assessment on volunteers foster future tests focused on: i) the possibility of developing and system embedding several sensing elements, and ii) to develop a wireless acquisition system, to allow comfortable and long-term acquisition in both patients and during sport activities.
2018
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
978-1-5386-3646-6
Humans
Monitoring, Physiologic
Respiratory Rate
Textiles
Silver
Wearable Electronic Devices
File in questo prodotto:
File Dimensione Formato  
conf.pdf

Accesso riservato

Descrizione: Publisher version
: Publisher’s version
Dimensione 905.23 kB
Formato Adobe PDF
905.23 kB Adobe PDF   Visualizza/Apri
committee.pdf

accesso aperto

Descrizione: Conference Committee
: Altro materiale allegato
Dimensione 2.52 MB
Formato Adobe PDF
2.52 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1163079
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 23
social impact