The objective of this paper is to provide an overview of the current status in neutron personal dosimetry based on poly allyl diglycol carbonate (PADC), also commonly known by the commercial name CR-39, to summarize the best practices in the field, and to point future research directions. An overview of the fundamentals of the technique is given, including a discussion on the PADC material, main parameters and characteristics, practical considerations, dosimetry approaches, and relevant standards. This work also summarizes the best practices adopted by individual monitoring services (IMSs) and discusses the research needed to improve the performance of this type of neutron dosimetry technique, as well as the challenges that make progress difficult. This work is based on the knowledge and experience of several laboratories and investigators and is part of the activities of the European Radiation Dosimetry Group (EURADOS) Working Group 2 – Harmonization of Individual Monitoring in Europe (WG2).

Neutron personal dosimetry using polyallyl diglycol carbonate (PADC): Current status, best practices and proposed research

Bolzonella, M.;Caresana, M.;
2022-01-01

Abstract

The objective of this paper is to provide an overview of the current status in neutron personal dosimetry based on poly allyl diglycol carbonate (PADC), also commonly known by the commercial name CR-39, to summarize the best practices in the field, and to point future research directions. An overview of the fundamentals of the technique is given, including a discussion on the PADC material, main parameters and characteristics, practical considerations, dosimetry approaches, and relevant standards. This work also summarizes the best practices adopted by individual monitoring services (IMSs) and discusses the research needed to improve the performance of this type of neutron dosimetry technique, as well as the challenges that make progress difficult. This work is based on the knowledge and experience of several laboratories and investigators and is part of the activities of the European Radiation Dosimetry Group (EURADOS) Working Group 2 – Harmonization of Individual Monitoring in Europe (WG2).
2022
neutron dosimetry; PADC; CR-39; Solid-State Nuclear Track Detector (SSNTD); passive dosimetry; personal detector
File in questo prodotto:
File Dimensione Formato  
2022 PADC Bolzonella WP2.pdf

accesso aperto

: Publisher’s version
Dimensione 6.13 MB
Formato Adobe PDF
6.13 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1219948
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 2
social impact