AIM: Spiral family implants (SFIs) are a new type of implant fixture with a conical internal helix and a variable thread design. The aim of this retrospective study was to evaluate the clinical outcomes of a series of SFIs. METHODS AND MATERIALS: A total of 234 SFIs were placed in 86 patients (55 females and 31 males, median age 53 years) during the period between May 2004 and November 2007. The mean follow-up was 13 months. Several host, surgery, and implant-related factors were investigated, and the Kaplan Meier algorithm and the Cox regression were used to detect variables associated with the clinical outcome. RESULTS: Only nine out of 234 implants were lost (i.e., survival rate (SVR) of 96.2\%) and no differences were detected among the studied variables. CONCLUSION: SFIs have a high SVR similar to those reported in previous studies on different implant types. CLINICAL SIGNIFICANCE: SFIs demonstrated a very high primary stability which offers the potential for use of a specific implant device for immediate loading. However, additional studies are necessary to verify their outcome on the medium/long period.

The clinical outcomes of 234 spiral family implants

CARINCI, Francesco
2009

Abstract

AIM: Spiral family implants (SFIs) are a new type of implant fixture with a conical internal helix and a variable thread design. The aim of this retrospective study was to evaluate the clinical outcomes of a series of SFIs. METHODS AND MATERIALS: A total of 234 SFIs were placed in 86 patients (55 females and 31 males, median age 53 years) during the period between May 2004 and November 2007. The mean follow-up was 13 months. Several host, surgery, and implant-related factors were investigated, and the Kaplan Meier algorithm and the Cox regression were used to detect variables associated with the clinical outcome. RESULTS: Only nine out of 234 implants were lost (i.e., survival rate (SVR) of 96.2\%) and no differences were detected among the studied variables. CONCLUSION: SFIs have a high SVR similar to those reported in previous studies on different implant types. CLINICAL SIGNIFICANCE: SFIs demonstrated a very high primary stability which offers the potential for use of a specific implant device for immediate loading. However, additional studies are necessary to verify their outcome on the medium/long period.
2009
M., Danza; O., Fromovich; R., Guidi; Carinci, Francesco
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1398564
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 20
  • ???jsp.display-item.citation.isi??? ND
social impact