Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes

Carregando...
Imagem de Miniatura

Data

2009-12-01

Autores

Cravo, JCM [UNESP]
Fiorelli, J
Lahr, FAR
Fonseca, R da [UNESP]
Cruz, VC da [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Fundação APINCO de Ciência e Tecnologia Avícolas

Resumo

This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by R statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling.

Descrição

Palavras-chave

Broiler house environment, recycled tiles, thermal comfort

Como citar

Revista Brasileira de Ciência Avícola. Fundação APINCO de Ciência e Tecnologia Avícolas, v. 11, n. 4, p. 219-224, 2009.