A twin TEPC with electric-field guard tubes has been constructed to be used to characterize the BNCT field of the irradiation facility of LENA reactor. One of the two mini TEPC was doped with 50 ppm of 10B in order to simulate the BNC events occurring in BNCT. By properly processing the two microdosimetric spectra, the gamma, neutron and BNC spectral components can be derived with good precision (~6%). However, direct measurements of 10B in some doped plastic samples, which were used for constructing the cathode walls, point out the scarce accuracy of the nominal 10B concentration value. The influence of the Boral® door, which closes the irradiation channel, has been measured. The gamma dose increases significantly (+ 51%) when the Boral® door is closed. The crypt-cell-regeneration weighting function has been used to measure the quality, namely the RBEμ value, of the radiation field in different conditions. The measured RBEμ values are only partially consistent with the RBE values of other BNCT facilities.

Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor

ALTIERI, SAVERIO;BORTOLUSSI, SILVA;PROTTI, NICOLETTA;POSTUMA, IAN
2014-01-01

Abstract

A twin TEPC with electric-field guard tubes has been constructed to be used to characterize the BNCT field of the irradiation facility of LENA reactor. One of the two mini TEPC was doped with 50 ppm of 10B in order to simulate the BNC events occurring in BNCT. By properly processing the two microdosimetric spectra, the gamma, neutron and BNC spectral components can be derived with good precision (~6%). However, direct measurements of 10B in some doped plastic samples, which were used for constructing the cathode walls, point out the scarce accuracy of the nominal 10B concentration value. The influence of the Boral® door, which closes the irradiation channel, has been measured. The gamma dose increases significantly (+ 51%) when the Boral® door is closed. The crypt-cell-regeneration weighting function has been used to measure the quality, namely the RBEμ value, of the radiation field in different conditions. The measured RBEμ values are only partially consistent with the RBE values of other BNCT facilities.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/843649
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 10
social impact