Although its role and importance is debated, Immunoscintigraphy (IS) remains a popular technique in Malignant Melanoma (MM) follow-up for postoperative assessment. Between April 1990 and December 1996, 287 consecutive patients underwent 650 IS examinations at our Department. Only data on 114 patients, operated up to December 1993, with a follow-up of at least 7 years are given here. IS results were compared to physical examination, to other imaging modalities and, where available, to histology. IS specificity and sensivity, concerning detection of melanoma metastases in lymph nodes, skin, brain, lung, visceral sites and bone, ranged from 37.5% and 22% to 100%. Our results indicate a high diagnostic accuracy of IS only for lymph node examination, but not for other possible locations of melanoma metastases. In our experience IS cannot be recommended for staging of melanoma patients, and should only be used in association with other imaging modalities.

Current role of Immunoscintigraphy in Malignant Melanoma follow-up. A study of 114 patients / Ribuffo, Diego; L., Cavalieri; F., De Vita; Massa, Rita; D., Prosperi; M., Tuccimei; Scuderi, Nicolo'. - In: JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH. - ISSN 0392-9078. - 20:1(2001), pp. 11-15.

Current role of Immunoscintigraphy in Malignant Melanoma follow-up. A study of 114 patients

RIBUFFO, Diego;MASSA, Rita;SCUDERI, Nicolo'
2001

Abstract

Although its role and importance is debated, Immunoscintigraphy (IS) remains a popular technique in Malignant Melanoma (MM) follow-up for postoperative assessment. Between April 1990 and December 1996, 287 consecutive patients underwent 650 IS examinations at our Department. Only data on 114 patients, operated up to December 1993, with a follow-up of at least 7 years are given here. IS results were compared to physical examination, to other imaging modalities and, where available, to histology. IS specificity and sensivity, concerning detection of melanoma metastases in lymph nodes, skin, brain, lung, visceral sites and bone, ranged from 37.5% and 22% to 100%. Our results indicate a high diagnostic accuracy of IS only for lymph node examination, but not for other possible locations of melanoma metastases. In our experience IS cannot be recommended for staging of melanoma patients, and should only be used in association with other imaging modalities.
2001
antibodies; malignant melanoma; scintigraphy
01 Pubblicazione su rivista::01a Articolo in rivista
Current role of Immunoscintigraphy in Malignant Melanoma follow-up. A study of 114 patients / Ribuffo, Diego; L., Cavalieri; F., De Vita; Massa, Rita; D., Prosperi; M., Tuccimei; Scuderi, Nicolo'. - In: JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH. - ISSN 0392-9078. - 20:1(2001), pp. 11-15.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/255189
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact