Objective: To find the optimal scan timing for early arterial phase hepatic CT with adequate arterial enhancement after the aortic contrast arrival. Methods: Sixty patients were divided randomly into three groups, each of which received 2.0 mL/kg of the 300 mgI/mL contrast medium with an injection duration of 30 seconds (Group A, mean rate 3.6 mL/sec); of 25 seconds (13, 4.6 mL/sec); of 30 seconds (3.6 mL/sec) followed by a saline chaser (C). Results: After the contrast arrival, aortic enhancement increased rapidly for 6-15 seconds (mean, 10 seconds) to the initial peak enhancement in all groups, and then, increased moderately to the maximum aortic enhancement over the following 19, 13, and 21 seconds, respectively. The mean maximum aortic enhancement in Group B (392 HU) and C (360 HU) were significantly higher than that in A (326 HU), respectively. The difference between the initial and maximum aortic enhancement was less than 50 HU. Conclusion: The optimal timing of the early arterial phase for hepatic CT arteriography is 10-15 seconds after the aortic arrival.

Determining the optimal timing for early arterial phase hepatic CT imaging by measuring abdominal aortic enhancement in variable contrast injection protocols / Takamichi, Murakami; Hiromitsu, Onishi; Koji, Mikami; Riccardo, Iannaccone; Michael P., Federle; Tonsok, Kim; Masatoshi, Hori; Atsuya, Okada; Taro, Marukawa; Hiroki, Higashihara; Passariello, Roberto; Hironobu, Nakamura. - In: JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY. - ISSN 0363-8715. - 30:2(2006), pp. 206-211. [10.1097/00004728-200603000-00007]

Determining the optimal timing for early arterial phase hepatic CT imaging by measuring abdominal aortic enhancement in variable contrast injection protocols

PASSARIELLO, Roberto;
2006

Abstract

Objective: To find the optimal scan timing for early arterial phase hepatic CT with adequate arterial enhancement after the aortic contrast arrival. Methods: Sixty patients were divided randomly into three groups, each of which received 2.0 mL/kg of the 300 mgI/mL contrast medium with an injection duration of 30 seconds (Group A, mean rate 3.6 mL/sec); of 25 seconds (13, 4.6 mL/sec); of 30 seconds (3.6 mL/sec) followed by a saline chaser (C). Results: After the contrast arrival, aortic enhancement increased rapidly for 6-15 seconds (mean, 10 seconds) to the initial peak enhancement in all groups, and then, increased moderately to the maximum aortic enhancement over the following 19, 13, and 21 seconds, respectively. The mean maximum aortic enhancement in Group B (392 HU) and C (360 HU) were significantly higher than that in A (326 HU), respectively. The difference between the initial and maximum aortic enhancement was less than 50 HU. Conclusion: The optimal timing of the early arterial phase for hepatic CT arteriography is 10-15 seconds after the aortic arrival.
2006
aorta; computed tomography (ct); contrast enhancement; ct; multi-detector row
01 Pubblicazione su rivista::01a Articolo in rivista
Determining the optimal timing for early arterial phase hepatic CT imaging by measuring abdominal aortic enhancement in variable contrast injection protocols / Takamichi, Murakami; Hiromitsu, Onishi; Koji, Mikami; Riccardo, Iannaccone; Michael P., Federle; Tonsok, Kim; Masatoshi, Hori; Atsuya, Okada; Taro, Marukawa; Hiroki, Higashihara; Passariello, Roberto; Hironobu, Nakamura. - In: JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY. - ISSN 0363-8715. - 30:2(2006), pp. 206-211. [10.1097/00004728-200603000-00007]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/27241
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 17
social impact