Fast scanning and efficient photodetection in a simple two-photon microscope.

MPS-Authors
/persons/resource/persons15910

Tan,  Y. P.
Research Group of Cellular Neurobiology, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15459

Llano,  I.
Research Group of Cellular Neurobiology, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15246

Hopt,  A.
Department of Membrane Biophysics, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons16055

Wuerriehausen,  F.
Department of Membrane Biophysics, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15570

Neher,  E.
Department of Membrane Biophysics, MPI for biophysical chemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Tan, Y. P., Llano, I., Hopt, A., Wuerriehausen, F., & Neher, E. (1999). Fast scanning and efficient photodetection in a simple two-photon microscope. Journal of Neuroscience Methods, 92(1-2), 123-135. doi:10.1016/S0165-0270(99)00103-X.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0012-FBD5-E
Abstract
Two-photon laser scan microscopy carries many advantages for work on brain slices and bulk tissue. However, it has very low signal levels compared to conventional fluorescence microscopy. This is disadvantageous in fast imaging applications when photon shot noise is limiting. Working on brain slices with excitation powers of 8–10 mW at the specimen plane, the resting signal from cerebellar Purkinje cell somas loaded with 10 μM Oregon Green 488 BAPTA-1 averaged 4 detected photons/μs; axons of interneurons loaded with 200 μM of this indicator yielded about 1 photon/μs. To obtain satisfactory images at high time resolution, long pixel dwell times are required and data collection should be restricted to as few pixels as necessary. Furthermore, a large proportion of total measurement time (duty cycle) should be available for data collection. We therefore developed a method for scanning small regions of interest with line repetition rates two to four times higher than conventional ones and a duty cycle of 70%. We also compared the performance of several photodetectors and found the optimum choice to depend strongly on the photon flux during a given application. For fluxes smaller than 5 photons/μs, the photon counting avalanche photodiode shows the best signal to noise ratio. At larger fluxes, photomultipliers or intensified photodiodes are superior.