Detection of minimal residual disease (MRD) in follow-up samples from patients with ALL is essential for evaluation of treatment response. We applied multicolor flow cytometry and real-time quantitative PCR (RQ-PCR) to compare MRD results in 71 follow-up samples from 22 children treated for ALL. When results obtained by flow cytometry and RQ-PCR were grouped into positive-negative categories, a significant level of agreement was found in 72% of samples (P<0.001). However, if a cutoff level of 0.01% was applied, the concordance was 89%. MRD could be quantified in 19 samples by both methods, showing a strong correlation (P<0.01). Nevertheless, MRD levels differed more than five-fold between both methods in 4/19 samples. In 20 (28%) samples, the two techniques showed discordant results. Most discordant results (17/20) were due to the limited sensitivity of flow cytometry analysis within the range 0.01-0.001%; remaining discordant results were due to the instable or subclonal IG/TCR gene rearrangements or a limited quantitative range of the applied RQ-PCR targets. Although concordant results could be obtained by flow cytometry and RQ-PCR analysis, MRD levels may differ. Therefore, MRD data obtained by these two techniques are not yet easily exchangeable.

, , , ,
doi.org/10.1038/sj.leu.2403444, hdl.handle.net/1765/73712
Leukemia
Department of Immunology

Malec, M., van der Velden, V., Björklund, E., Wijkhuijs, A., Söderhäll, S., Mazur, P., … Porwit-MacDonald, A. (2004). Analysis of minimal residual disease in childhood acute lymphoblastic leukemia: Comparison between RQ-PCR analysis of Ig/TcR gene rearrangements and multicolor flow cytometric immunophenotyping. Leukemia, 18(10), 1630–1636. doi:10.1038/sj.leu.2403444