Advanced search
1 file | 1.97 MB Add to list

Airtightness of the window–wall interface in cavity brick walls

Nathan Van Den Bossche (UGent) , Willem Huyghe (UGent) , Jan Moens (UGent) , Arnold Janssens (UGent) and Michel De Paepe (UGent)
(2012) ENERGY AND BUILDINGS. 45. p.32-42
Author
Organization
Keywords
Airtightness, Error analysis, Brick cavity wall, Window-wall interface, ENERGY USE

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 1.97 MB

Citation

Please use this url to cite or link to this publication:

MLA
Van Den Bossche, Nathan, et al. “Airtightness of the Window–Wall Interface in Cavity Brick Walls.” ENERGY AND BUILDINGS, vol. 45, 2012, pp. 32–42, doi:10.1016/j.enbuild.2011.10.022.
APA
Van Den Bossche, N., Huyghe, W., Moens, J., Janssens, A., & De Paepe, M. (2012). Airtightness of the window–wall interface in cavity brick walls. ENERGY AND BUILDINGS, 45, 32–42. https://doi.org/10.1016/j.enbuild.2011.10.022
Chicago author-date
Van Den Bossche, Nathan, Willem Huyghe, Jan Moens, Arnold Janssens, and Michel De Paepe. 2012. “Airtightness of the Window–Wall Interface in Cavity Brick Walls.” ENERGY AND BUILDINGS 45: 32–42. https://doi.org/10.1016/j.enbuild.2011.10.022.
Chicago author-date (all authors)
Van Den Bossche, Nathan, Willem Huyghe, Jan Moens, Arnold Janssens, and Michel De Paepe. 2012. “Airtightness of the Window–Wall Interface in Cavity Brick Walls.” ENERGY AND BUILDINGS 45: 32–42. doi:10.1016/j.enbuild.2011.10.022.
Vancouver
1.
Van Den Bossche N, Huyghe W, Moens J, Janssens A, De Paepe M. Airtightness of the window–wall interface in cavity brick walls. ENERGY AND BUILDINGS. 2012;45:32–42.
IEEE
[1]
N. Van Den Bossche, W. Huyghe, J. Moens, A. Janssens, and M. De Paepe, “Airtightness of the window–wall interface in cavity brick walls,” ENERGY AND BUILDINGS, vol. 45, pp. 32–42, 2012.
@article{1980203,
  author       = {{Van Den Bossche, Nathan and Huyghe, Willem and Moens, Jan and Janssens, Arnold and De Paepe, Michel}},
  issn         = {{0378-7788}},
  journal      = {{ENERGY AND BUILDINGS}},
  keywords     = {{Airtightness,Error analysis,Brick cavity wall,Window-wall interface,ENERGY USE}},
  language     = {{eng}},
  pages        = {{32--42}},
  title        = {{Airtightness of the window–wall interface in cavity brick walls}},
  url          = {{http://doi.org/10.1016/j.enbuild.2011.10.022}},
  volume       = {{45}},
  year         = {{2012}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: