Advanced search
1 file | 14.96 KB Add to list

Determination of the resolution limit of a whole body PET scanner using monte carlo simulations

Author
Organization
Abstract
We studied the resolution limit that can be obtained for a whole body PET scanner. The results were obtained using a Monte Carlo based simulation program. The influence of two parameters was investigated: the crystal pixel size and the number of layers used for Depth-Of-Interaction (DOI) correction.
Keywords
medical imaging

Downloads

  • Abstract HendrikThoen EMBSBenelux 2011.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 14.96 KB

Citation

Please use this url to cite or link to this publication:

MLA
Thoen, Hendrik, et al. “Determination of the Resolution Limit of a Whole Body PET Scanner Using Monte Carlo Simulations.” Belgian Day on Biomedical Engineering, 10th, Abstracts, edited by M. Nyssen, Koninklijke Vlaamse Academie (KVAB), 2011.
APA
Thoen, H., Keereman, V., Mollet, P., & Vandenberghe, S. (2011). Determination of the resolution limit of a whole body PET scanner using monte carlo simulations. In M. Nyssen (Ed.), Belgian day on Biomedical Engineering, 10th, Abstracts. Koninklijke Vlaamse Academie (KVAB).
Chicago author-date
Thoen, Hendrik, Vincent Keereman, Pieter Mollet, and Stefaan Vandenberghe. 2011. “Determination of the Resolution Limit of a Whole Body PET Scanner Using Monte Carlo Simulations.” In Belgian Day on Biomedical Engineering, 10th, Abstracts, edited by M. Nyssen. Koninklijke Vlaamse Academie (KVAB).
Chicago author-date (all authors)
Thoen, Hendrik, Vincent Keereman, Pieter Mollet, and Stefaan Vandenberghe. 2011. “Determination of the Resolution Limit of a Whole Body PET Scanner Using Monte Carlo Simulations.” In Belgian Day on Biomedical Engineering, 10th, Abstracts, ed by. M. Nyssen. Koninklijke Vlaamse Academie (KVAB).
Vancouver
1.
Thoen H, Keereman V, Mollet P, Vandenberghe S. Determination of the resolution limit of a whole body PET scanner using monte carlo simulations. In: Nyssen M, editor. Belgian day on Biomedical Engineering, 10th, Abstracts. Koninklijke Vlaamse Academie (KVAB); 2011.
IEEE
[1]
H. Thoen, V. Keereman, P. Mollet, and S. Vandenberghe, “Determination of the resolution limit of a whole body PET scanner using monte carlo simulations,” in Belgian day on Biomedical Engineering, 10th, Abstracts, Brussels, Belgium, 2011.
@inproceedings{2140171,
  abstract     = {{We studied the resolution limit that can be obtained for a whole body PET scanner. The results were obtained using a Monte Carlo based simulation program. The influence of two parameters was investigated: the crystal pixel size and the number of layers used for Depth-Of-Interaction (DOI) correction.}},
  articleno    = {{D/2011/0455/04}},
  author       = {{Thoen, Hendrik and Keereman, Vincent and Mollet, Pieter and Vandenberghe, Stefaan}},
  booktitle    = {{Belgian day on Biomedical Engineering, 10th, Abstracts}},
  editor       = {{Nyssen, M.}},
  isbn         = {{9789065690982}},
  keywords     = {{medical imaging}},
  language     = {{eng}},
  location     = {{Brussels, Belgium}},
  pages        = {{1}},
  publisher    = {{Koninklijke Vlaamse Academie (KVAB)}},
  title        = {{Determination of the resolution limit of a whole body PET scanner using monte carlo simulations}},