Polymer integrated waveguide optical biosensor by using spectral splitting effect

(2017) PHOTONIC SENSORS. 7(2). p.131-139
Author
Organization
Project
Abstract
The polymer waveguide optical biosensor based on the Mach-Zehnder interferometer (MZI) by using spectral splitting effect is investigated. The MZI based biosensor has two unequal width sensing arms. With the different mode dispersion responses of the two-arm waveguides to the cladding refractive index change, the spectral splitting effect of the output interference spectrum is obtained, inducing a very high sensitivity. The influence of the different mode dispersions between the two-arm waveguides on the spectral splitting characteristic is analyzed. By choosing different lengths of the two unequal width sensing arms, the initial dip wavelength of the interference spectrum and the spectral splitting range can be controlled flexibly. The polymer waveguide optical biosensor is designed, and its sensing property is analyzed. The results show that the sensitivity of the polymer waveguide optical biosensor by using spectral splitting effect is as high as 104 nm/RIU, with an improvement of 2-3 orders of magnitude compared with the slot waveguide based microring biosensor.
Keywords
MACH-ZEHNDER INTERFEROMETER, CRITICAL SENSITIVITY, SENSOR, DEVICES, DESIGN, Optical biosensor, integrated waveguide, spectral splitting, sensitivity

Downloads

  • pub 2026.pdf
    • full text (Published version)
    • |
    • open access
    • |
    • PDF
    • |
    • 708.34 KB

Citation

Please use this url to cite or link to this publication:

MLA
Han, Xiaonan, et al. “Polymer Integrated Waveguide Optical Biosensor by Using Spectral Splitting Effect.” PHOTONIC SENSORS, vol. 7, no. 2, Springer Nature, 2017, pp. 131–39, doi:10.1007/s13320-017-0395-3.
APA
Han, X., Han, X., Shao, Y., Wu, Z., Liang, Y., Teng, J., … Zhao, M. (2017). Polymer integrated waveguide optical biosensor by using spectral splitting effect. PHOTONIC SENSORS, 7(2), 131–139. https://doi.org/10.1007/s13320-017-0395-3
Chicago author-date
Han, Xiaonan, Xiuyou Han, Yuchen Shao, Zhenlin Wu, Yuxin Liang, Jie Teng, Shuhui Bo, Geert Morthier, and Mingshan Zhao. 2017. “Polymer Integrated Waveguide Optical Biosensor by Using Spectral Splitting Effect.” PHOTONIC SENSORS 7 (2): 131–39. https://doi.org/10.1007/s13320-017-0395-3.
Chicago author-date (all authors)
Han, Xiaonan, Xiuyou Han, Yuchen Shao, Zhenlin Wu, Yuxin Liang, Jie Teng, Shuhui Bo, Geert Morthier, and Mingshan Zhao. 2017. “Polymer Integrated Waveguide Optical Biosensor by Using Spectral Splitting Effect.” PHOTONIC SENSORS 7 (2): 131–139. doi:10.1007/s13320-017-0395-3.
Vancouver
1.
Han X, Han X, Shao Y, Wu Z, Liang Y, Teng J, et al. Polymer integrated waveguide optical biosensor by using spectral splitting effect. PHOTONIC SENSORS. 2017;7(2):131–9.
IEEE
[1]
X. Han et al., “Polymer integrated waveguide optical biosensor by using spectral splitting effect,” PHOTONIC SENSORS, vol. 7, no. 2, pp. 131–139, 2017.
@article{8539365,
  abstract     = {{The polymer waveguide optical biosensor based on the Mach-Zehnder interferometer (MZI) by using spectral splitting effect is investigated. The MZI based biosensor has two unequal width sensing arms. With the different mode dispersion responses of the two-arm waveguides to the cladding refractive index change, the spectral splitting effect of the output interference spectrum is obtained, inducing a very high sensitivity. The influence of the different mode dispersions between the two-arm waveguides on the spectral splitting characteristic is analyzed. By choosing different lengths of the two unequal width sensing arms, the initial dip wavelength of the interference spectrum and the spectral splitting range can be controlled flexibly. The polymer waveguide optical biosensor is designed, and its sensing property is analyzed. The results show that the sensitivity of the polymer waveguide optical biosensor by using spectral splitting effect is as high as 104 nm/RIU, with an improvement of 2-3 orders of magnitude compared with the slot waveguide based microring biosensor.}},
  author       = {{Han, Xiaonan and Han, Xiuyou and Shao, Yuchen and Wu, Zhenlin and Liang, Yuxin and Teng, Jie and Bo, Shuhui and Morthier, Geert and Zhao, Mingshan}},
  issn         = {{1674-9251}},
  journal      = {{PHOTONIC SENSORS}},
  keywords     = {{MACH-ZEHNDER INTERFEROMETER,CRITICAL SENSITIVITY,SENSOR,DEVICES,DESIGN,Optical biosensor,integrated waveguide,spectral splitting,sensitivity}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{131--139}},
  publisher    = {{Springer Nature}},
  title        = {{Polymer integrated waveguide optical biosensor by using spectral splitting effect}},
  url          = {{http://doi.org/10.1007/s13320-017-0395-3}},
  volume       = {{7}},
  year         = {{2017}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: