Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-35419
Titel: Outcomes of conduction system pacing compared to right ventricular pacing as a primary strategy for treating bradyarrhythmia: systematic review and meta-analysis
VerfasserIn: Abdin, Amr
Aktaa, Suleman
Vukadinović, Davor
Arbelo, Elena
Burri, Harran
Glikson, Michael
Meyer, Christian
Munyombwe, Theresa
Nielsen, Jens Cosedis
Ukena, Christian
Vernooy, Kevin
Gale, Chris P.
Sprache: Englisch
Titel: Clinical Research in Cardiology
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2021
Freie Schlagwörter: Cardiac pacing
His‐bundle pacing
Left bundle branch pacing
Clinical outcomes
Meta-analysis
Systematic review
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background Right ventricular pacing (RVP) may cause electrical and mechanical desynchrony leading to impaired left ventricular ejection fraction (LVEF). We investigated the outcomes of RVP with His bundle pacing (HBP) and left bundle branch pacing (LBBP) for patients requiring a de novo permanent pacemaker (PPM) for bradyarrhythmia. Methods and results Systematic review of randomized clinical trials and observational studies comparing HBP or LBP with RVP for de novo PPM implantation between 01 January 2013 and 17 November 2020 was performed. Random and fixed effects meta-analyses of the effect of pacing technology on outcomes were performed. Study outcomes included all-cause mortality, heart failure hospitalization (HFH), LVEF, QRS duration, lead revision, atrial fibrillation, procedure parameters, and pacing metrics. Overall, 9 studies were included (6 observational, 3 randomised). HBP compared with RVP was associated with decreased HFH (risk ratio [RR] 0.68, 95% confidence interval [CI] 0.49–0.94), preservation of LVEF (mean difference [MD] 0.81, 95% CI − 1.23 to 2.85 vs. − 5.72, 95% CI − 7.64 to -3.79), increased procedure duration (MD 15.17 min, 95% CI 11.30–19.04), and increased lead revisions (RR 5.83, 95% CI 2.17–15.70, p = 0.0005). LBBP compared with RVP was associated with shorter paced QRS durations (MD 5.6 ms, 95% CI − 6.4 to 17.6) vs. (51.0 ms, 95% CI 39.2–62.9) and increased procedure duration (MD 37.78 min, 95% CI 20.04–55.51). Conclusion Of the limited studies published, this meta-analysis found that HBP and LBBP were superior to RVP in maintaining physiological ventricular activation as an initial pacing strategy.
DOI der Erstveröffentlichung: 10.1007/s00392-021-01927-7
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-354199
hdl:20.500.11880/32346
http://dx.doi.org/10.22028/D291-35419
ISSN: 1861-0692
1861-0684
Datum des Eintrags: 7-Feb-2022
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Innere Medizin
Professur: M - Keiner Professur zugeordnet
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
Abdin2021_Article_OutcomesOfConductionSystemPaci.pdf2,29 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons