Purpose Fluoroscopy is an invaluable tool in various medical practices such as catheterization or image-guided surgery.Patient’sscreenforprolongedtimerequiressubstantial reductioninX-rayexposure:Thelimitednumberofphotons generates relevant quantum noise. Denoising is essential to enhance fluoroscopic image quality and can be considerably improved by considering the peculiar noise characteristics. This study presents analytical models of fluoroscopic noise to express the variance of noise as a function of gray level, a practical method to estimate the parameters of the modelsandapossibleapplicationtoimprovetheperformanceof noise filtering. Methods QuantumnoiseismodeledasaPoissondistribution andresultsstronglysignal-dependent.However,fluoroscopic devicesgenerallyapplygray-leveltransformations(i.e.,logarithmic-mapping, gamma-correction) for image enhancement. The resulting statistical transformations of the noise were analytically derived. In addition, a characterization of thestatisticsofnoiseforfluoroscopicimagedifferenceswas offered by resorting to Skellam distribution. Real fluoroscopic sequences of a simple step-phantom were acquired by a conventional fluoroscopic device and were utilized as actual noise measurements to compare with. An adaptive spatio-temporal filter based on the local conditional average of similar pixels has been proposed. The gray-level differencesbetweenthelocalpixelandtheneighboringpixelshave been assumed as measure of similarity. Filter performance was evaluated by using real fluoroscopic images of a step phantom and acquired during a pacemaker implantation. Results The comparison between experimental data and the analytical derivation of the relationship between noise variance and mean pixel intensity (noise-parameter models) were presented relatively to raw-images, after applying logarithmic-mapping or gamma-correction and for difference images. Results have confirmed a great agreement (adjusted R-squaredvalues>0.8).Clippingeffectsofrealsensorswere also addressed. A fine image restoration has been obtained by using a conditioned spatio-temporal average filter based on the noise statistics previously estimated. Discussion Fluoroscopicnoisemodelingisusefultodesign effectiveproceduresfornoiseestimationandimagefiltering. Inparticular,filterperformance analysishas showed thatthe knowledge of the noise model and the accurate estimate of noisecharacteristicscansignificantlyimprovetheimagerestoration, especially for edge preserving. Fluoroscopic image enhancement can support further X-ray exposure reduction, medical image analysis and automated object identification (i.e., surgery tools, anatomical structures).

X-ray fluoroscopy noise modeling for filter design

Romano M;
2013-01-01

Abstract

Purpose Fluoroscopy is an invaluable tool in various medical practices such as catheterization or image-guided surgery.Patient’sscreenforprolongedtimerequiressubstantial reductioninX-rayexposure:Thelimitednumberofphotons generates relevant quantum noise. Denoising is essential to enhance fluoroscopic image quality and can be considerably improved by considering the peculiar noise characteristics. This study presents analytical models of fluoroscopic noise to express the variance of noise as a function of gray level, a practical method to estimate the parameters of the modelsandapossibleapplicationtoimprovetheperformanceof noise filtering. Methods QuantumnoiseismodeledasaPoissondistribution andresultsstronglysignal-dependent.However,fluoroscopic devicesgenerallyapplygray-leveltransformations(i.e.,logarithmic-mapping, gamma-correction) for image enhancement. The resulting statistical transformations of the noise were analytically derived. In addition, a characterization of thestatisticsofnoiseforfluoroscopicimagedifferenceswas offered by resorting to Skellam distribution. Real fluoroscopic sequences of a simple step-phantom were acquired by a conventional fluoroscopic device and were utilized as actual noise measurements to compare with. An adaptive spatio-temporal filter based on the local conditional average of similar pixels has been proposed. The gray-level differencesbetweenthelocalpixelandtheneighboringpixelshave been assumed as measure of similarity. Filter performance was evaluated by using real fluoroscopic images of a step phantom and acquired during a pacemaker implantation. Results The comparison between experimental data and the analytical derivation of the relationship between noise variance and mean pixel intensity (noise-parameter models) were presented relatively to raw-images, after applying logarithmic-mapping or gamma-correction and for difference images. Results have confirmed a great agreement (adjusted R-squaredvalues>0.8).Clippingeffectsofrealsensorswere also addressed. A fine image restoration has been obtained by using a conditioned spatio-temporal average filter based on the noise statistics previously estimated. Discussion Fluoroscopicnoisemodelingisusefultodesign effectiveproceduresfornoiseestimationandimagefiltering. Inparticular,filterperformance analysishas showed thatthe knowledge of the noise model and the accurate estimate of noisecharacteristicscansignificantlyimprovetheimagerestoration, especially for edge preserving. Fluoroscopic image enhancement can support further X-ray exposure reduction, medical image analysis and automated object identification (i.e., surgery tools, anatomical structures).
2013
Noise modeling; X-ray fluoroscopy; Poisson quantum noise
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/5639
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? ND
social impact