Recalibration significantly reduced bias of the Jaffe method. For pediatric samples, recalibrated Jaffe results do not comply with either the imprecision goal or the total error based on biological variability. Adult recalibrated Jaffe results are in compliance with the goals based on biological variability and with the acceptance criteria from the NKDEP.
Couchoud Cécile, Pozet Nicole, Labeeuw Michel, Pouteil-Noble Claire, Screening early renal failure: Cut-off values for serum creatinine as an indicator of renal impairment, 10.1046/j.1523-1755.1999.00411.x
Swedko Peter J., Clark Heather D., Paramsothy Koushi, Akbari Ayub, Serum Creatinine Is an Inadequate Screening Test for Renal Failure in Elderly Patients, 10.1001/archinte.163.3.356
Narayanan S, Clin Chem, 26, 1119 (1980)
Star R, Clin Chem, 48, 1375 (2002)
Levey A. S., Coresh J., Greene T., Marsh J., Stevens L. A., Kusek J. W., Van Lente F., , Expressing the Modification of Diet in Renal Disease Study Equation for Estimating Glomerular Filtration Rate with Standardized Serum Creatinine Values, 10.1373/clinchem.2006.077180
Levey AS, Ann Intern Med, 150, 604 (2009)
Kallner A., Khatami Z., How does the MDRD Study equation compare with serum creatinine in routine healthcare? Anatomy of MDRD‐eGFR, 10.1080/00365510802144789
Pottel Hans, Hoste Liesbeth, Martens Frank, New insights in glomerular filtration rate formulas and chronic kidney disease classification, 10.1016/j.cca.2010.05.031
Levey AS, Ann Intern Med, 139, 137 (2003)
Poggio Emilio D., Nef Patrick C., Wang Xuelei, Greene Tom, Van Lente Frederick, Dennis Vincent W., Hall Phillip M., Performance of the Cockcroft-Gault and Modification of Diet in Renal Disease Equations in Estimating GFR in Ill Hospitalized Patients, 10.1053/j.ajkd.2005.04.023
Myers G. L., Recommendations for Improving Serum Creatinine Measurement: A Report from the Laboratory Working Group of the National Kidney Disease Education Program, 10.1373/clinchem.2005.0525144
Miller WG, Arch Pathol Lab Med, 129, 297 (2005)
Perrone R, Clin Chem, 38, 1933 (1992)
Blass KG, Z Klin Chem Klin Biochem, 12, 336 (1974)
Kroll MH, Clin Chem, 33, 1129 (1987)
O'Leary N, Clin Chem, 38, 1749 (1992)
Srisawasdi P., Chaichanajarernkul U., Teerakanjana N., Vanavanan S., Kroll M.H., Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods, 10.1002/jcla.20350
Lolekha Porntip H., Jaruthunyaluck Sukchai, Srisawasdi Pornpen, Deproteinization of serum: Another best approach to eliminate all forms of bilirubin interference on serum creatinine by the kinetic Jaffe reaction, 10.1002/jcla.1013
Junge Wolfgang, Wilke Baerbel, Halabi Atef, Klein Gerhard, Determination of reference intervals for serum creatinine, creatinine excretion and creatinine clearance with an enzymatic and a modified Jaffé method, 10.1016/j.cccn.2004.02.007
Hicks JM, Clin Chem, 25, 1005 (1979)
Dimeski Goce, McWhinney Brett, Jones Brock, Mason Rebecca, Carter Andrew, Extent of bilirubin interference with Beckman creatinine methods, 10.1258/acb.2007.007079
Delanghe J, Acta Clin Belg, 57, 172 (2002)
on behalf of the IFCC Scientific Di International Federation of Clinica, Enzymatic assays for creatinine: time for action, 10.1515/cclm.2008.113
Coresh Josef, Astor Brad C., McQuillan Geraldine, Kusek John, Greene Tom, Van Lente Frederick, Levey Andrew S., Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate glomerular filtration rate, 10.1053/ajkd.2002.32765
Dodder N. G., Tai S. S.-C., Sniegoski L. T., Zhang N. F., Welch M. J., Certification of Creatinine in a Human Serum Reference Material by GC-MS and LC-MS, 10.1373/clinchem.2007.090027
Wolf S, Clin Chem, 54, A212 (2008)
Cobbaert C. M., Baadenhuijsen H., Weykamp C. W., Prime Time for Enzymatic Creatinine Methods in Pediatrics, 10.1373/clinchem.2008.116863
Stöckl D, Clin Chem, 9, 993 (1993)
Thienpont LM, Clin Chem, 39, 1001 (1993)
Martin Bland J., Altman DouglasG., STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT, 10.1016/s0140-6736(86)90837-8
Henderson A.Ralph, Webb Sharon, Richardson H., Wood Donald E., A comparison of pooled, fresh-frozen, and lyophilized sera as a matrix for enzyme proficiency testing: The experience of the Ontario laboratory proficiency testing program, 10.1016/0009-9120(95)02046-2
Chesher D, Clin Biochem Rev, 29, S23 (2008)
Xie F, Clin Chem, 54, A214 (2008)
Vickery S., Does the ID-MS traceable MDRD equation work and is it suitable for use with compensated Jaffe and enzymatic creatinine assays?, 10.1093/ndt/gfl249
Delanghe Joris R., Cobbaert Christa, Galteau Marie-Madeleine, Harmoinen Aimo, Jansen Rob, Kruse Rolf, Laitinen Päivi, Thienpont Linda M., Wuyts Birgitte, Weykamp Cas, Panteghini Mauro, Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group, 10.1515/cclm.2008.256
Wuyts B., Reevaluation of Formulas for Predicting Creatinine Clearance in Adults and Children, Using Compensated Creatinine Methods, 10.1373/49.6.1011
Kempermann F, Glomerular filtration rate estimation from plasma creatinine after inhibition of tubular secretion: relevance of the creatinine assay, 10.1093/ndt/14.5.1247
Crocker H, Shephard M D, White G H, Evaluation of an enzymatic method for determining creatinine in plasma., 10.1136/jcp.41.5.576