Intravascular BOLD signal characterization of balanced SSFP experiments in human blood at high to ultrahigh fields

MPS-Authors
/persons/resource/persons214685

Pérez-Rodas,  M
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84145

Pohmann,  R
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons216029

Heule,  R
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Pérez-Rodas, M., Pohmann, R., Scheffler, K., & Heule, R. (2021). Intravascular BOLD signal characterization of balanced SSFP experiments in human blood at high to ultrahigh fields. Magnetic Resonance in Medicine, 85(4), 2055-2068. doi:10.1002/mrm.28575.


Cite as: https://hdl.handle.net/21.11116/0000-0007-54C4-D
Abstract

Purpose: To investigate the intravascular contribution to the overall balanced SSFP (bSSFP) BOLD effect in human blood at high to ultrahigh field strengths (3 T, 9.4 T, and 14.1 T).

Methods: Venous blood prepared at two different oxygenation levels (deoxygenated: Y ≈ 71%, oxygenated: Y ≈ 94%) was measured with phase-cycled bSSFP for varying TRs/flip angles at 3 T, 9.4 T, and 14.1 T. The oxygen sensitivity was analyzed by intrinsic MIRACLE (motion-insensitive rapid configuration relaxometry)-R2 estimation and passband signal differences. The intravascular BOLD-related signal change was extracted from the measured data for microvasculature and macrovasculature, and compared with the extravascular contribution obtained by Monte Carlo simulations.

Results: The MIRACLE-R2 values showed a characteristic increase with longer TRs in deoxygenated blood, corroborating that SE-R2 data cannot be used to assess the intravascular bSSFP BOLD effect. Passband bSSFP signal differences measured at optimal flip angles of 30° at 3 T and 20° at 9.4 T/14.1 T revealed considerable relative intravascular contributions of 95%/70% at 3 T, 74%/43% at 9.4 T, 66%/46% at 14.1 T for TR = 5 ms, and 90%/65% at 3 T, 36%/27% at 9.4 T, 13%/15% at 14.1 T for TR = 10 ms in macrovascular/microvascular regimes.

Conclusion: The results indicate that intravascular effects have to be considered to better understand the origin of bSSFP BOLD contrast in functional MRI experiments, especially at short TRs. The MIRACLE-R2 method demonstrated the ability to quantify the apparent decrease in R2 due to rapid RF refocusing.