Abstract: lt is theoretically studied both flow and Pressure loss of a directly cooled coated particle element with distributing and collecting channels. Pressure conditions for a representative element were measured and compared with the calculations . lt is shown by numerous calculations and by a considered FRJ-2 fuel element in how far afuel element has to follow the geometrical lay-out in order to satisfy the optimum requirements of flow and heat techniques. The distribution of the coolant in the fuel Iayer and the therefrom resulting temperature distribution were calculated by considering a Zarge variation of fuel element length, coated particle diameter, hollow tute resistance, and flow direction ; this is presented by figures .