Home > Publications database > Measurements of ion energy distribution on a plasma gun |
Book/Report | FZJ-2016-04683 |
; ; ;
1961
Kernforschungsanlage Jülich Zentralbibliothek, Verlag
Jülich
Please use a persistent id in citations: http://hdl.handle.net/2128/12276
Report No.: Juel-0022-PP
Abstract: Time resolved energy distributions of ions of the plasma ejected by a hydromagnetic gun have been measured by a retarding potential spectrometer. Three pulses corresponding to different periods of origin are observed and analyzed. The longitudinal energy of the ions is in the range from 200 eV to about 1 keV, the ion temperature being of the order of 1 eV. The influence of diaphragms and the retarding field on the plasma is studied and discussed.
The record appears in these collections: |