Book/Report FZJ-2017-06141

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Automatische Zeitschaltuhr für fotographische Debye-Scherrer-Messung von Kristallpulvern

 ;  ;

1972
Kernforschungsanlage Jülich, Verlag Jülich

Jülich : Kernforschungsanlage Jülich, Verlag, Berichte der Kernforschungsanlage Jülich 862, 6, 13 p. ()

Please use a persistent id in citations:

Report No.: Juel-0862-AC

Abstract: For the quantitative determination of crystal powder mixtures the photographie Debye-Scherrer technique offers considerableadvantages over measurements using Geiger-Muller counter goniometer. Firstly, smaller amounts can be analysed and secondly, the particular geometry of the ray path permits the analysis of coarser crystal powders. The disadvantages of the Debye-Scherrer technique are the additional work to develope the films, the increased possibility of errors when many films are developed, the preparing of characteristic curves to determine the relative intensities of single-phase powders, and the necessary photometric measurements. When a Weisenberg goniometer and exposures with small aperture are used the first two disadvantages can be omitted by combining many diffraction pattern on the same film. To minimize the work when preparing the sequence of exposuresfor the characteristic curves and to increase the measuring accuracy for standard mixtures an automatic time clock was developed. It opens and shuts a window in the X-ray path of the X-ray apparatus (e.g. Philips, PW 1316) for a pre-fixed time and controls the advance of the carriage of a Weisenberg goniometer (e.g. Enrof-Nonius Y800, figure 1) between two consecutive X-ray exposures.An apparatus for the subsequent automatic photometry of the films with step-scanning by a Microdensitometer II (Enraf-Nonius) and the recording of the photometric values on punch tape of a teleprinter (Teletype ASR 33) is at present developed.


Contributing Institute(s):
  1. Publikationen vor 2000 (PRE-2000)
Research Program(s):
  1. 899 - ohne Topic (POF3-899) (POF3-899)

Database coverage:
OpenAccess
Click to display QR Code for this record

The record appears in these collections:
Document types > Reports > Reports
Document types > Books > Books
Workflow collections > Public records
Institute Collections > Retrocat
Publications database
Open Access

 Record created 2017-08-28, last modified 2021-01-29


OpenAccess:
Download fulltext PDF
External link:
Download fulltextFulltext by OpenAccess repository
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)