Design and comparison of different types of dual-frequency matching networks used in double-tuned coils for multinuclear magnetic resonance imaging and spectroscopy

 ;  ;  ;

2022
IEEE New York, NY

IEEE access 10, 123899 - 123904 () [10.1109/ACCESS.2022.3223731]

This record in other databases:  

Please use a persistent id in citations:   doi:

Abstract: Multi-resonant RF coils are often used in multinuclear MR imaging and/or spectroscopy experiments, and a large variety of strategies for multi-tuning coils exist. However, designing a multi-tuned coil with good performance is challenging, and improvements in sensitivity are always desirable - particularly on the X-nucleus coil due to the intrinsically lower MR sensitivity of non-proton nuclei. In this work, various dual-frequency matching networks in double-tuned coils are compared, and their effect on the coil performance is investigated. Four different dual-frequency matching networks were designed and constructed with frequency-splitting or -blocking traps, which enable exploration of both proton-1 (1H) and sodium-23 (23Na) nuclei. Two single-frequency matching networks were also built without any additional lossy components as a reference, and their matchings were set to either the 1H or the 23Na frequency. The initial evaluation was conducted on the bench using a network analyser to examine the scattering (S)-parameters and quality factors of the connected RF coils. The performance of the attached matching networks was then further evaluated by measuring the corresponding signal-to-noise ratio (SNR) based on images obtained at a 7 T clinical MRI scanner. It was found that even though the tuning and matching conditions were nearly impeccable in the S-parameters, the actual 1H SNR decreased significantly due to the inserted traps, whereas the SNRs of the 23Na frequency were nearly maintained with the added traps and the losses were much less. The dual-frequency matching networks create additional sensitivity loss, which is dependent on the actual implementation of the matching circuit. This is in agreement with previously reported results associated with the evaluation of inserted double-tuning traps for RF coils.

Classification:

Contributing Institute(s):
  1. Physik der Medizinischen Bildgebung (INM-4)
  2. Jara-Institut Quantum Information (INM-11)
  3. Jülich-Aachen Research Alliance - Translational Brain Medicine (JARA-BRAIN)
Research Program(s):
  1. 5253 - Neuroimaging (POF4-525) (POF4-525)

Appears in the scientific report 2022
Database coverage:
Medline ; Creative Commons Attribution CC BY 4.0 ; DOAJ ; OpenAccess ; Article Processing Charges ; Clarivate Analytics Master Journal List ; Current Contents - Electronics and Telecommunications Collection ; Current Contents - Engineering, Computing and Technology ; DOAJ Seal ; Essential Science Indicators ; Fees ; IF < 5 ; JCR ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > INM > INM-11
Institute Collections > INM > INM-4
Workflow collections > Public records
Workflow collections > Publication Charges
Publications database
Open Access

 Record created 2022-11-22, last modified 2023-05-31


OpenAccess:
Download fulltext PDF
External link:
Download fulltextFulltext by OpenAccess repository
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)