In this paper a proton Computed Radiography (pCR) apparatus for medical applications, realized by PRIMA (PRoton IMAging) Italian Collaboration, is described. The system is oriented to acquire tomography images and meets clinical demands for the use of protons in radiotherapy treatments. The approach proposed here is based on 'single proton tracking' method with Most Likely Path (MLP) reconstruction of the single particle. A pCR prototype, with a field of view of about 5×5 cm2 and an acquisition time of the order of 10 s (10 kHz, 105 events), has been developed and tested with a 62 MeV proton beam at the INFN-Laboratori Nazionali del Sud (LNS). The apparatus architecture will be described and first proton radiographies will be shown.

PRIMA: An apparatus for medical application / V.Sipala; M.Brianzi; M.Bruzzi; M.Bucciolini; GAP.Cirrone; C.Civinini; G.Cuttone; D.Lo Presti; S.Pallotta; N.Randazzo; F.Romano; C.Stancampiano; M.Scaringella; C.Talamonti; M.Tesi. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 658:(2011), pp. 73-77. [10.1016/j.nima.2011.05.025]

PRIMA: An apparatus for medical application

BRUZZI, MARA;BUCCIOLINI, MARTA;PALLOTTA, STEFANIA;SCARINGELLA, MONICA;TALAMONTI, CINZIA;
2011

Abstract

In this paper a proton Computed Radiography (pCR) apparatus for medical applications, realized by PRIMA (PRoton IMAging) Italian Collaboration, is described. The system is oriented to acquire tomography images and meets clinical demands for the use of protons in radiotherapy treatments. The approach proposed here is based on 'single proton tracking' method with Most Likely Path (MLP) reconstruction of the single particle. A pCR prototype, with a field of view of about 5×5 cm2 and an acquisition time of the order of 10 s (10 kHz, 105 events), has been developed and tested with a 62 MeV proton beam at the INFN-Laboratori Nazionali del Sud (LNS). The apparatus architecture will be described and first proton radiographies will be shown.
2011
658
73
77
V.Sipala; M.Brianzi; M.Bruzzi; M.Bucciolini; GAP.Cirrone; C.Civinini; G.Cuttone; D.Lo Presti; S.Pallotta; N.Randazzo; F.Romano; C.Stancampiano; M.Scaringella; C.Talamonti; M.Tesi
File in questo prodotto:
File Dimensione Formato  
PRIMA An apparatus for medical application.pdf

Accesso chiuso

Tipologia: Altro
Licenza: Tutti i diritti riservati
Dimensione 949.53 kB
Formato Adobe PDF
949.53 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/597647
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact