Article (Scientific journals)
Using total error as decision criterion in analytical method transfer
Dewé, Walthère; Govaerts, Bernadette; Boulanger, Bruno et al.
2007In Chemometrics and Intelligent Laboratory Systems, 85 (2), p. 262-268
Peer Reviewed verified by ORBi
 

Files


Full Text
FinalTransferWally.pdf
Publisher postprint (633.66 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
analytical method; transfer; accuracy; total error; tolerance interval; consumer risk; producer risk
Abstract :
[en] An analytical transfer is a complete process that consists in transferring a validated analytical method from a sending laboratory (called sender) to a receiving laboratory (called receiver) after having experimentally demonstrated that it also masters the method. The decision to transfer an analytical method is usually taken based on the combination of two criteria: one about systematic error and one about random errors. These usual criteria, their combination and their limitations are described in this paper. As it is for method validation, total error-based approaches should be also considered in method transfer. Two approaches are proposed in order to have a total error-based criterion and to take into account the precision of the true value estimate. In the first approach, a beta-expectation tolerance interval similar to the one used in method validation is calculated and then compared to acceptance limits around the estimate of the true value. The second approach, found as slightly more powerful than the first one, consists in estimating the probability to have a result outside these acceptance limits. (c) 2006 Elsevier B.V. All rights reserved.
Disciplines :
Chemistry
Computer science
Author, co-author :
Dewé, Walthère ;  Université de Liège - ULiège > Analyse des médicaments
Govaerts, Bernadette;  Université Catholique de Louvain > Institut de Statistique
Boulanger, Bruno ;  Université de Liège - ULiège > Département de pharmacie > Analyse des médicaments
Rozet, Eric ;  Université de Liège - ULiège > Chimie analytique
Chiap, Patrice ;  Université de Liège - ULiège > Département de pharmacie > Analyse des médicaments
Hubert, Philippe  ;  Université de Liège - ULiège > Chimie analytique
Language :
English
Title :
Using total error as decision criterion in analytical method transfer
Publication date :
15 February 2007
Journal title :
Chemometrics and Intelligent Laboratory Systems
ISSN :
0169-7439
eISSN :
1873-3239
Publisher :
Elsevier Science Bv, Amsterdam, Netherlands
Volume :
85
Issue :
2
Pages :
262-268
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 19 January 2009

Statistics


Number of views
219 (13 by ULiège)
Number of downloads
8 (3 by ULiège)

Scopus citations®
 
40
Scopus citations®
without self-citations
24
OpenCitations
 
38

Bibliography


Similar publications



Contact ORBi