Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/73704
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Dry deposition of pollutant and marker particles onto live mouse airway surfaces enhances monitoring of individual particle mucociliary transit behaviour
Author: Donnelley, M.
Morgan, K.
Siu, K.
Parsons, D.
Citation: Journal of Synchrotron Radiation, 2012; 19(4):551-558
Publisher: Munksgaard Int Publ Ltd
Issue Date: 2012
ISSN: 0909-0495
1600-5775
Statement of
Responsibility: 
M. Donnelley, K.S. Morgan, K.K.W. Siu and D.W. Parsons
Abstract: Particles suspended in the air are inhaled during normal respiration and unless cleared by airway defences, such as the mucociliary transit (MCT) system, they can remain and affect lung and airway health. Synchrotron phase-contrast X-ray imaging (PCXI) methods have been developed to non-invasively monitor the behaviour of individual particles in live mouse airways and in previous studies the MCT behaviour of particles and fibres in the airways of live mice after deposition in a saline carrier fluid have been examined. In this study a range of common respirable pollutant particles (lead dust, quarry dust and fibreglass fibres) as well as marker particles (hollow glass micro-spheres) were delivered into the trachea of live mice using a dry powder insufflator to more accurately mimic normal environmental particulate exposure and deposition via inhalation. The behaviour of the particles once delivered onto the airway surface was tracked over a five minute period via PCXI. All particles were visible after deposition. Fibreglass fibres remained stationary throughout while all other particle types transited the tracheal surface throughout the imaging period. In all cases the majority of the particle deposition and any airway surface activity was located close to the dorsal tracheal wall. Both the individual and bulk motions of the glass bead marker particles were visible and their behaviour enabled otherwise hidden MCT patterns to be revealed. This study verified the value of PCXI for examining the post-deposition particulate MCT behaviour in the mouse trachea and highlighted that MCT is not a uniform process as suggested by radiolabel studies. It also directly revealed the advantages of dry particle delivery for establishing adequate particulate presence for visualizing MCT behaviour. The MCT behaviour and rate seen after dry particle delivery was different from that in previous carrier-fluid studies. It is proposed that dry particle delivery is essential for producing environmentally realistic particle deposition and studying how living airway surfaces handle different types of inhaled particles by MCT processes.
Keywords: Particles
pollution
airway surface
lung
trachea
mucociliary transit
non-invasive
X-ray imaging
phase contrast
mouse
Rights: Copyright © International Union of Crystallography
DOI: 10.1107/S0909049512018250
Published version: http://dx.doi.org/10.1107/s0909049512018250
Appears in Collections:Aurora harvest 5
Paediatrics publications

Files in This Item:
File Description SizeFormat 
hdl_73704.pdfPublished version449.75 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.