Title: A more accurate reconstruction system matrix for quantitative proton computed tomography
Author: Penfold, S.
Rosenfeld, A.
Schulte, R.
Schubert, K.
Citation: Medical Physics, 2009; 36(10):4511-4518
Publisher: Amer AssocPhysicists Amer Inst Physics
Issue Date: 2009
ISSN: 0094-2405
2473-4209
Statement of
Responsibility: 
S. N. Penfold, A. B. Rosenfeld, R. W. Schulte and K. E. Schubert
Abstract: An accurate system matrix is required for quantitative protonCT (pCT) image reconstruction with iterative projection algorithms. The system matrix is composed of chord lengths of individual proton path intersections with reconstruction pixels. In previous work, reconstructions were performed assuming constant intersection chord lengths, which led to systematic errors of the reconstructedprotonstopping powers. The purpose of the present work was to introduce a computationally efficient variable intersection chord length in order to improve the accuracy of the system matrix. An analytical expression that takes into account the discrete stepping nature of the pCT most likely path (MLP) reconstruction procedure was created to describe an angle-dependent effective mean chord length function. A pCT dataset was simulated with GEANT4 using a parallel beam of 200 MeV protons intersecting a computerized head phantom consisting of tissue-equivalent materials with known relative stopping power. The phantom stopping powers were reconstructed with the constant chord length, exact chord length, and effective mean chord length approaches, in combination with the algebraic reconstruction technique. Relative stopping power errors were calculated for each anatomical phantom region and compared for the various methods. It was found that the error of approximately 10% in the mean reconstructedstopping power value for a given anatomical region, resulting from a system matrix with a constant chord length, could be reduced to less than 0.5% with either the effective mean chord length or exact chord length approaches. Reconstructions with the effective mean chord length were found to be approximately 20% faster than reconstructions with an exact chord length. The effective mean chord length method provides the possibility for more accurate, computationally efficient quantitative pCT reconstructions.
Keywords: Proton computed tomography
iterative projection methods
system matrix, chord length
Rights: © 2009 American Association of Physicists in Medicine.
DOI: 10.1118/1.3218759
Published version: http://dx.doi.org/10.1118/1.3218759
Appears in Collections:Aurora harvest 4
Physics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.