Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/59884
Title: Reliability of the estimation of total hepatic blood flow by doppler ultrasound in patients with cirrhotic portal hypertension
Author: Berzigotti, Annalisa
Reverter, Enric
García-Criado, Angeles
González-Abraldes Iglesias, Juan
Cerini, Federica
García Pagán, Juan Carlos
Bosch i Genover, Jaume
Keywords: Hipertensió portal
Cirrosi hepàtica
Ecografia Doppler
Portal hypertension
Hepatic cirrhosis
Doppler ultrasonography
Issue Date: 10-May-2013
Publisher: Elsevier
Abstract: BACKGROUND & AIMS: Hepatic blood flow (HBF) is best estimated by the Fick's method during indocyanine green constant infusion (ICG-HBF) on hepatic vein catheterization. We investigated the consistency and agreement of HBF measured by Doppler ultrasound (US-HBF) as compared with ICG-HBF in portal hypertensive patients with cirrhosis. METHODS: In 50 patients observed for HVPG measurement (56% compensated; Child score 7 ± 2; HVPG 16.6 ± 6.0 mmHg; varices in 75%) US-HBF (Sequoia-512-Acuson; 4.5-7 MHz convex probe; US-HBF = hepatic artery blood flow+portal vein blood flow) and ICG-HBF (Fick's method after an equilibration period of at least 45 min of ICG bolus of 5 mg + constant rate infusion of 0.2 mg/min). Intraclass correlation coefficient (ICC) for consistency and absolute agreement between US-HBF and ICG-HBF were calculated. RESULTS: Mean ICG-HBF and US-HBF were similar, being respectively 1004 ± 543 ml/min and 994 ± 494 ml/min (p = 0.661 vs. ICG-HBF). However, results in individual patients disclosed marked differences between the two methods (386 ± 415 ml/min) and showed only moderate consistency (ICC 0.456; p < 0.0001), absolute agreement (ICC 0.461; p < 0.0001) and linear correlation (R = 0.464; p < 0.0001). The discrepancy between the two methods was maximal in patients with poor liver function, high HBF by any technique and more arterialized liver circulation. Hepatic artery blood flow ≥40% of US-HBF indicated, with 90% specificity, a discrepancy ≥20% between US-HBF and ICG-HBF. CONCLUSIONS: HBF estimations by Doppler-ultrasound and ICG are significantly correlated, but their discrepancy in individual cases is high. Estimation of HBF by Doppler-US should be considered unreliable in patients with poor hepatic function and large liver arterialization.
Note: Versió postprint del document publicat a: http:/dx.doi.org/10.1016/j.jhep.2013.04.037
It is part of: Journal of Hepatology, 2013, vol. 59, num. 4, p. 717-722
URI: http://hdl.handle.net/2445/59884
Related resource: http://dx.doi.org/10.1016/j.jhep.2013.04.037
ISSN: 0168-8278
Appears in Collections:Articles publicats en revistes (Medicina)