Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/98111
Title: | A high-sensitivity 135GHz millimeter-wave imager by compact split-ring-resonator in 65-nm CMOS | Authors: | Li, Nan Yu, Hao Yang, Chang Shang, Yang Li, Xiuping Liu, Xiong |
Issue Date: | 2015 | Source: | Li, N., Yu, H., Yang, C., Shang, Y., Li, X., & Liu, X. (2015). A high-sensitivity 135GHz millimeter-wave imager by compact split-ring-resonator in 65-nm CMOS. Solid-State Electronics, 113, 54-60. | Conference: | Solid-state electronics | Abstract: | A high-sensitivity 135 GHz millimeter-wave imager is demonstrated in 65 nm CMOS by on-chip metamaterial resonator: a differential transmission-line (T-line) loaded with split-ring-resonator (DTL-SRR). Due to sharp stop-band introduced by the metamaterial load, high-Q oscillatory amplification can be achieved with high sensitivity when utilizing DTL-SRR as quench-controlled oscillator to provide regenerative detection. The developed 135 GHz mm-wave imager pixel has a compact core chip area of 0.0085 mm2 with measured power consumption of 6.2 mW, sensitivity of −76.8 dBm, noise figure of 9.7 dB, and noise equivalent power of 0.9 fW/√(Hz) Hz. Millimeter-wave images has been demonstrated with millimeter-wave imager integrated with antenna array. | URI: | https://hdl.handle.net/10356/98111 http://hdl.handle.net/10220/38545 |
DOI: | 10.1016/j.sse.2015.05.006 | Schools: | School of Electrical and Electronic Engineering | Rights: | © 2015 Elsevier Ltd. This is the author created version of a work that has been peer reviewed and accepted for publication by Solid-State Electronics, Elsevier Ltd. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.sse.2015.05.006]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Conference Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
A high-sensitivity 135GHz millimeter-wave imager .pdf | 1.06 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
50
1
Updated on Mar 27, 2024
Web of ScienceTM
Citations
50
1
Updated on Oct 30, 2023
Page view(s) 50
528
Updated on Mar 27, 2024
Download(s) 20
223
Updated on Mar 27, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.