Compartir
Citas
Título
A reproducible and repeatable digital method for quantifying nasal and sinus airway changes following suture palatine expansion
Autor(es)
Palabras clave
Orthodontics
Suture palatal expansion
Maxillary sinus
Nasal airway
Rapid maxillary expansion
Clasificación UNESCO
3213 Cirugía
Fecha de publicación
2022-08-17
Editor
Springer
Citación
Tzironi, G., Zubizarreta-Macho, Á., Guinot-Barona, C. et al. (2022). A reproducible and repeatable digital method for quantifying nasal and sinus airway changes following suture palatine expansion. Sleep Breath. https://doi.org/10.1007/s11325-022-02691-2
Resumen
[EN] Purpose The airway complex is modifed by palatine expansion. Computer tomography has been used in the past to determine the change in volume, but there was a lack of a specifc, reproducible method for this purpose. The present study sought to determine the accuracy, reproducibility, and repeatability of an innovative digital measurement technique for analyzing the volume of maxillary and nasal sinus airways following suture palatine expansion performed with the Hyrax disyuntor
appliance.Methods Patients underwent preoperative and postoperative cone-beam computed tomography (CBCT) scans. The datasets were subsequently uploaded into a digital treatment planning software to record the volume of the right and left maxillary sinus, as well as the nasal and maxillary sinus airway complex. The Gage Repeatability & Reproducibility statistical analysis methodology was used to evaluate the repeatability and reproducibility of this measurement technique when measuring the volume of maxillary and nasal sinus airways following suture palatine expansion with the Hyrax disyuntor appliance. Additionally, comparative analysis between preoperative and postoperative measures was performed using Student’s t-test for statistical analysis.Results In 5 patients, paired t-tests found statistically signifcant diferences before and after treatment in the volumes of the left maxillary sinus (p=0.002), right maxillary sinus (p=0.001), and nasal and maxillary sinus airway complex (p=0.005) after suture palatine expansion with the Hyrax disyuntor appliance.
Conclusion The proposed digital technique is an accurate, repeatable, and reproducible measurement technique for analyzing the volume of maxillary and nasal sinus airways following suture palatine expansion using the Hyrax disyuntor.
URI
ISSN
1520-9512
DOI
10.1007/s11325-022-02691-2
Versión del editor
Aparece en las colecciones
Patrocinador
Publicación en abierto financiada por el Consorcio de Bibliotecas Universitarias de Castilla y León (BUCLE), con cargo al Programa Operativo 2014ES16RFOP009 FEDER 2014-2020 DE CASTILLA Y LEÓN, Actuación:20007-CL - Apoyo Consorcio BUCLE.
Ficheros en el ítem
Tamaño:
1.383Mb
Formato:
Adobe PDF