• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
  • Contacto
  • Sugerencias
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.
    Gredos. Repositorio documental de la Universidad de SalamancaUniversidad de Salamanca
    Consorcio BUCLE Recolector

    Listar

    Todo GredosComunidades y ColeccionesPor fecha de publicaciónAutoresMateriasTítulosEsta colecciónPor fecha de publicaciónAutoresMateriasTítulos

    Mi cuenta

    AccederRegistro

    Estadísticas

    Ver Estadísticas de uso

    ENLACES Y ACCESOS

    Derechos de autorPolíticasGuías de autoarchivoFAQAdhesión USAL a la Declaración de Berlín

    COMPARTIR

    Ver ítem 
    •   Gredos Principal
    • Repositorio Científico
    • Grupos de Investigación
    • GIASO. Avances en Salud Oral
    • GIASO. Artículos
    • Ver ítem
    •   Gredos Principal
    • Repositorio Científico
    • Grupos de Investigación
    • GIASO. Avances en Salud Oral
    • GIASO. Artículos
    • Ver ítem

    Compartir

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Título
    Comparison of Clinical and Histologic Outcomes of Zirconia Versus Titanium Implants Placed in Fresh Sockets: A 5-Month Study in Beagles.
    Autor(es)
    Montero Martín, JavierAutoridad USAL ORCID
    Bravo, Manuel
    Guadilla González, YasminaAutoridad USAL
    Portillo, María
    Blanco Antona, Leticia AlejandraAutoridad USAL
    Rojo, Rosa
    Rosales-Leal, J Ignacio
    López-Valverde Centeno, AntonioAutoridad USAL
    Rosales-Leal, Ignacio
    Palabras clave
    histomorphometry
    immediate implant
    osseointegration
    titanium
    zirconia
    Fecha de publicación
    2015
    Citación
    Montero J, Bravo M, Guadilla Y, et al. Comparison of Clinical and Histologic Outcomes of Zirconia Versus Titanium Implants Placed in Fresh Sockets: A 5-Month Study in Beagles. Int J Oral Maxillofac Implants. 2015;30(4):10.11607/jomi.3668. doi:10.11607/jomi.3668
    Resumen
    [EN]Purpose: This study evaluated the clinical and histomorphometric results of titanium (Ti) and custom-made zirconia (Zr) implants placed into fresh extraction sockets in beagles that did not receive oral hygiene attention or a softened diet during postoperative healing. Materials and Methods: The roughness of the Ti and Zr implant surfaces was assessed by confocal microscopy. In eight beagle dogs, four implants each (two Ti and two Zr) were placed in the distal sockets of the third and fourth premolars with the implant shoulder at the bone crest and subjected to submerged healing. Standardized radiographs were taken after placement and 5 months after placement (at sacrifice). Histologic and histomorphometric measurements were performed on nondecalcified histologic sections. The main outcome measures included implant survival, bone-implant contact (BIC), and bone loss on the buccal and lingual plates. Results: Topographic analysis showed significant differences between the Zr and Ti surfaces. Roughness was higher for Ti than for Zr implants, kurtosis was close to 3 for Ti, and skewness was negative for Zr. After 5 months, the mean BIC was similar for the Zr (57.0% ± 15.2%) and Ti (56.5% ± 14.4%) implants, and the most severe bone loss site was observed on the buccal wall. The risk of failure was significantly higher for the Zr (43.8%) than for the Ti (12.5%) implants. Conclusion: The implant failure rate for the Zr implants was 3.5 times higher than that of the Ti implants. This may be partially explained by the less favorable topography of the Zr implants, which had, on average, significantly lower roughness (Ra = 0.85 ± 0.04 μm), negative skewness of the surface profile (-1.56 ± 0.27), and higher kurtosis (7.88 ± 1.99).
    URI
    http://hdl.handle.net/10366/162509
    ISSN
    0882-2786
    DOI
    10.11607/jomi.3668
    Versión del editor
    http://dx.doi.org/10.11607/jomi.3668
    Aparece en las colecciones
    • GIASO. Artículos [10]
    Mostrar el registro completo del ítem
    Ficheros en el ítem
    Nombre:
    JOMI_30_4_Montero_773 (1).pdf
    Tamaño:
    220.1Kb
    Formato:
    Adobe PDF
    Descripción:
    Artículo
    Thumbnail
    Visualizar/Abrir
     
    Universidad de Salamanca
    AVISO LEGAL Y POLÍTICA DE PRIVACIDAD
    2024 © UNIVERSIDAD DE SALAMANCA
     
    Universidad de Salamanca
    AVISO LEGAL Y POLÍTICA DE PRIVACIDAD
    2024 © UNIVERSIDAD DE SALAMANCA